This paper presents the design of a printed step-type monopole antenna for biological tissue analysis and medical imaging applications in the microwave frequency range. The design starts from a very simple and widely known rectangular monopole antenna, and different modifications to the antenna geometry are made in order to increase the bandwidth. The antenna dimensions are optimized by means of a parametric analysis of each dimension using a 3-D electromagnetic simulator based on the finite element method. The optimized antenna, with final dimensions of 40 × 36 mm2, is manufactured onto a low-cost FR4 (fiber glass epoxy) substrate. The characteristics of the antenna have been measured inside an anechoic chamber, obtaining an omnidirectional radiation pattern and a working frequency range between 2.7 GHz and 11.4 GHz, which covers the UWB frequencies and enables the use of the antenna in medical imaging applications. Finally, the behaviour of four of these antennas located around a realistic breast model, made with biocompatible materials, has been analysed with the electromagnetic simulator, obtaining good results and demonstrating the usefulness of the designed antenna in the proposed application.
Background: The vertical transmission of severe acute respiratory coronavirus-2 (SARS-CoV-2) remains highly debated. Here, we evaluated SARS-CoV-2-transmission in newborns with intrauterine conditions. Methods: This was a prospective, observational and multicentric study involving 13 Spanish hospitals included in the GEStational and NEOnatal-COVID cohort. Pregnant women with microbiologically confirmed SARS-CoV-2 infection during any trimester of pregnancy or delivery and their newborns were included from March to November 2020. Demographic, clinical and microbiological data were also obtained. Viral loads were analyzed in different maternal and newborn biological samples (placenta, breast milk and maternal blood; urine, meconium and newborn blood). Results: A total of 177 newborns exposed to SARS-CoV-2 were included. Newborns were tested by reverse transcriptase-polymerase chain reaction using nasopharyngeal swabs within the first 24–48 hours of life and at 14 days of life. In total 5.1% were considered to have SARS-CoV-2 infection in the neonatal period, with 1.7% considered intrauterine and 3.4% intrapartum or early postnatal transmission cases. There were no differences in the demographic and clinical characteristics of the pregnant women and their newborns’ susceptibility to infections in their perinatal history or background. Conclusions: Intrauterine transmission of SARS-CoV-2 is possible, although rare, with early postnatal transmission occurring more frequently. Most infected newborns remained asymptomatic or had mild symptoms that evolved well during follow-up. We did not find any maternal characteristics predisposing infants to neonatal infection. All infected newborn mothers had acute infection at delivery. Although there was no presence of SARS-CoV2 in cord blood or breast milk samples, SARS-CoV-2 viral load was detected in urine and meconium samples from infected newborns.
This work introduces a microwave-based system able to detect tumours in breast phantoms in a non-invasive way. The data acquisition system is composed of a hardware system which involves high-frequency components (antennas, switches and cables), a microcontroller, a vector network analyser used as measurement instrument and a computer devoted to the control and automation of the operation of the system. Concerning the software system, the computer runs a Python script which is in charge of mastering and automatising all the required stages for the data acquisition, from initialisation of the hardware system to performing and saving the measurements. We also report on the design of the high-performance broadband antenna used to carry out the measurements, as well as on the algorithm employed to build the final medical images, based on an adapted version of the so-called Improved Delay-and-Sum (IDAS) algorithm improved by a Hamming window filter and averaging preprocessing. The calibration and start-up of the system are also described. The experimental validation includes the use of different tumour models with different dielectric properties inside the breast phantom. The results show promising tumour detection capabilities, even when there is low dielectric contrast between the tumoural and healthy tissues, as is the usual case for dense breasts in young women.
A radio frequency (RF)-based system for surgical navigation is presented. Surgical navigation technologies are widely used nowadays for aiding the surgical team with many interventions. However, the currently available options still pose considerable limitations, such as line-of-sight occlusion prevention or restricted materials and equipment allowance. In this work, we suggest a different approach based on a microwave broadband antenna system. We combine techniques from microwave medical imaging, which can overcome the current limitations in surgical navigation technologies, and we propose methods to develop RF-based systems for real-time tracking neurosurgical tools. The design of the RF system to perform the measurements is shown and discussed, and two methods (Multiply and Sum and Delay Multiply and Sum) for building the medical images are analyzed. From these measurements, a surgical tool’s position tracking system is developed and experimentally assessed in an emulated surgical scenario. The reported results are coherent with other approaches found in the literature, while overcoming their main practical limitations. The discussion of the results discloses some hints on the validity of the system, the optimal configurations depending on the requirements, and the possibilities for future enhancements.
Fund through the ACIF pre-doctoral program, grant number ACIF/2020/147. The work of J.M.V.-S. is supported by the Conselleria d'Educació, Investigació, Cultura i Esport (GVA) through FDGENT/2018/015 project.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.