The adoption of mini-bypass significantly potentially reduces hemodilution, donor blood usage, postoperative bleeding and exposure to GME in routine CABG patients as compared to the use of conventional extracorporeal circulation circuits.
Neurological complications remain an important cause of morbidity and mortality of patients following cardiopulmonary bypass (CPB). Microemboli, as well as cerebral hypoperfusion, are the main postulated mechanisms. This study demonstrates that the insertion of a dynamic bubble trap (DBT) into the curcuit reduces microbubbles in the arterial line and microembolic signals (MES) in the middle cerebral arteries (MCAs). We investigated 12 patients during coronary artery bypass grafting (CABG). The DBT was inserted between the arterial filter and the arterial cannula. For detection of microemboli before and after the DBT, a special ultrasound Doppler device was used. MES were detected by transcranial Doppler monitoring in both MCAs of the patients. Microbubbles and MES were counted during bypass. These data were compared to 12 patients who were operated in a previous period without the use of a DBT. There were no significant differences in both groups with respect to gender, age, crossclamp and bypass time and number of anastomoses. In the group without a DBT in the circuit, a mean of 6311 microbubbles per operation could be observed distal to the arterial filter, corresponding to 282 MES. After inclusion of a DBT, we could register, in the second group, 8496 microemboli proximal and 2915 distal of the DBT, corresponding to 89 MES per operation. The reduction rate of microbubbles in the tubing was 65.7%, corresponding to a reduction in MES of about 86.2%. We conclude that the insertion of a DBT in the arterial line of CPB circuit protects the cerebrovascular system from microembolic events, as demonstrated by lower MES counts.
Microemboli during extracorporeal circulation (ECC) might be a reason for postoperative neuropsychological dysfunction. This case report shows that reduction of microbubbles in the arterial line, as well as high intensity transient signals (HITS) in the middle cerebral artery (MCA), could be accomplished by use of a dynamic bubble trap (DBT) during routine coronary artery bypass graft (CABG) surgery in a 63-year-old male. The DBT was placed after the arterial filter, an ultrasound Doppler device was used for detection of microemboli before and after the DBT. HITS were measured by a transcranial ultrasound Doppler in both MCAs. For first 32 min of ECC, the DBTwas excluded; 54 916 microbubbles and 507 HITS were counted. In the next 30 min, blood flow was directed through the DBT. This led to a significant reduction of microbubbles from 55 888 to 18 237; accordingly, only 120 HITS were registered. A DBT, integrated in ECC for routine CABG, effectively reduces air bubbles, thus protecting the cerebrovascular system from microembolization, as demonstrated by lower HITS counts.
We would like to bring to your notice the matter of duplicated publication in our article 'Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective' [1].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.