The aim of the National Quality Registries is to monitor the outcome of healthcare given to patients. The Swedish Quality register for otosclerosis surgery is one of the nine official national registers for ear, nose and throat diseases in Sweden. Since 2004, surgical and audiological results and patient satisfaction scores have been systematically collected from a majority of the ear, nose and throat clinics performing stapes surgery in Sweden. The results of 1688 patients who underwent primary operations for otosclerosis were evaluated for 24 out of totally 26 clinics performing stapes surgery, between 2004 and 2010. The most common surgical technique reported was stapedotomy accomplished in an overnight stay. A majority of patients experienced improved hearing, and were satisfied with the preoperative counselling. Successful surgery, defined as an ABG closure ≤10 dB HL, was achieved in 69%, improvement in AC by ≥20 dB in 63% and BC not worsened by more than ≥5 dB in 93% of the patients. An overall low incidence of postoperative complications was reported. The outcome for ABG and BC was demonstrated to be independent of the number of operations performed by each clinic. An evaluation of the register and the results from the SQOS revealed that stapes surgery is a safe procedure with good hearing outcomes, low complication rates and a high rate of patient’s satisfaction on a national level.
Objective measurements are important for programming cochlear implants in young children and other individuals who cannot participate in behavioral measurements. AutoNRT, the automatic method used to record responses from the auditory nerve in the Cochlear Ltd., implant system, is often used as a basis for estimating the threshold level and comfort level (C-level) for these patients. However, it has not been sufficiently established if AutoNRT measurements remain consistent over time.This study aimed to determine if/when AutoNRT thresholds stabilize.The study design was a longitudinal prospective study.AutoNRT thresholds were obtained from 52 young children and 80 adults. All subjects received the same implant (CI24RE Contour Advance).AutoNRT thresholds were measured on all intracochlear electrodes during the surgery and at the initial activation. During the following year, children were measured at 1, 3, 6, and 12 months, and adults were measured at 6 and 12 months. The results were analyzed based on mean values, correlation, and absolute mean differences.There were large variations for all electrodes between the intraoperative and postoperative AutoNRT thresholds of both children and adults. For children, the thresholds were considered to be stable from 1 month. The correlations obtained between the last two measurements, 6 and 12 months, for both children and adults were generally high for all electrodes.The present results demonstrate the importance of repeating the AutoNRT measurement postoperatively, at about 1 month after initial activation, to obtain reliable and stable thresholds for estimating the T- and C-level profiles.
Purpose The aim of the study was to investigate hearing outcomes in stapes revision surgery with regard to the type of clinic (university clinic or county clinic). Furthermore, the aim was to investigate the risk of complications with a focus on tinnitus, hearing deterioration, and taste disturbance 1 year after surgery. Methods The study is based on data from the Swedish Quality Register for Otosclerosis Surgery (SQOS). Two study protocols were completed by the surgeon, and a questionnaire was distributed to the patients 1 year after surgery. A total of 156 revisions were available for analysis with both preoperative and postoperative audiometry data. Results Seventy-five percent of the patients reported better to much better hearing 1 year after revision surgery. An air bone gap ≤ 20 dB postoperatively was seen in 77% of the patients. Four percent had hearing deterioration ≥ 20 dB PTA4 AC. Eleven percent had worsened or newly developed tinnitus, 5% had taste disturbance, and 3% had dizziness 1 year after surgery. Preoperative and postoperative hearing did not differ between patients operated on in university vs. county clinics. Conclusions Revision surgery in otosclerosis is a challenge for otologists, but no differences in hearing outcomes between university and county clinics were found in this nationwide study. The risk of hearing deterioration and deafness is higher than in primary stapes surgery, and revision surgery should be recommended primarily in cases with a large air–bone gap and moderate to severe preoperative hearing loss.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.