In this paper, magnetic resonance imaging (MRI) is investigated for monitoring small and large lesions created by high-intensity focused ultrasound (HIFU) in freshly excised lamb brain and in rabbit brain in vivo. A single-element spherically focused transducer of 5 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A prototype MRI-compatible positioning device that is used to navigate the transducer is described. The effects of HIFU were investigated using T1-W and T2-W fast spin echo (FSE) and fluid-attenuated inversion recovery (FLAIR). T2-W FSE and FLAIR show better anatomical details within the brain than T1-W FSE, but with T1-W FSE, the contrast between lesion and brain is higher for both thermal and bubbly lesions. The best contrast between lesion and brain with T1-W FSE is obtained with TR above 500 ms, whereas with T2-W FSE, the best contrast is observed between 40 and 60 ms. The maximum contrast to noise ratio (CNR) measured with T1-W FSE was approximately 20. With T2-W FSE, the corresponding CNR was approximately 12. With this system, we were able to create large lesions (by producing overlapping lesions), and it was possible to monitor these lesions with MRI with excellent contrast. The length of the lesions in vivo brain was much higher than the length in vitro, indicating that the penetration in the in vitro brain is limited, possibly by reflection due to trapped bubbles in the blood vessels. This paper demonstrates that HIFU has the potential to treat brain tumors in humans. This could be done either using a single-element transducer with a frequency around 1 MHZ or using a multi-element transducer.
Magnetic Resonance Imaging (MRI) was utilized to monitor lesions created at temperature below the boiling point and lesions created at temperature above the boiling point using High Intensity Focused Ultrasound (HIFU) in freshly excised kidney, liver and brain and in vivo rabbit kidney and brain. T2-weighted fast spin echo (FSE) was proven as an excellent MRI sequence that can detect lesions with temperature above the boiling point in kidney. This advantage is attributed to the significant difference in signal intensity between the cavity and the thermal lesion. In liver the MRI sequence of Proton Density is recommended to detect lesions above boiling. In brain T1-W FSE was the optimum pulse sequence to detect lesions of either type. In order to monitor the temperature elevation during a HIFU exposure, T1-weighted fast spoiled gradient (FSPGR) was used. The shape of the focal temperature distribution was uniform with the absence of boiling, whereas with an exposure affected by boiling, the temperature distribution could be of irregular shape, demonstrating the drastic effects taking place during boiling. In order to confirm that boiling occurred, the temperature was estimated using the widely used method of Proton Resonance Frequency (PRF) shift
This is the accepted version of the paper.This version of the publication may differ from the final published version.
Permanent repository link
a b s t r a c tThe aim of this study was to evaluate a flat rectangular (3 Â 10 mm 2 ) MRI compatible transducer operating at 5 MHz. The main task was to explore the feasibility of creating deep lesions in heart at a depth of at least 15 mm. The size of thermal necrosis in heart tissue was estimated as a function of power and time using a simulation model. The system was then tested in an excised lamb heart. In this study, we were able to create lesions of 15 mm deep with acoustic power of 6 W for an exposure of approximately 1 min. The contrast to noise ratio (CNR) between lesion and heart tissue was evaluated using fast spin echo (FSE). The CNR value was approximately 22 using T1 W FSE. Maximum CNR was achieved with repetition time (TR) between 300 and 800 ms. Using T2W FSE, the corresponding CNR was approximately 13 for the 14 in vivo experiments. The average lesion depth was 11.93 mm with a standard deviation of 0.62 mm. In vivo irradiation conditions were 6 W for 60 s. The size of the lesion in the other two dimensions was close to 3 Â 10 mm 2 (size of the transducer element).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.