This study in a lung model suggests that placing an injector more than 8 cm proximal to a laryngotracheal stenosis will prevent changes in intrapulmonary pressure related to the degree of stenosis or driving pressure during HFJV. The location of the injector chosen for clinical care should balance the need for effective ventilation with the risk of barotrauma.
The breakdown voltage of the biocompatible polymer Parylene C was determined after storage in 60°C saline solution and treatment by autoclave. It occurred that both, storage at 60°C in saline solution and autoclaving, lead to distinct decrease of dielectric strength by approximately 50%.
Background
Currently, many patients suffering from dementia do not have a diagnosis when admitted to geriatric hospitals. This is the case despite an increased risk of complications affecting the length of stay and outcome. Unfortunately, many dementia screening tests cannot be used on geriatric inpatients, who are often bedridden. Therefore, we aimed at evaluating the diagnostic accuracy of a small battery of bedside tasks that require minimal vision and fine motor skills in patients with suspected dementia.
Methods
In this prospective study, the Bamberg Dementia Screening Test (BDST) was administered to a consecutive series of 1295 patients referred for neuropsychological testing. The diagnosis of dementia was confirmed in 1159 and excluded in 136 patients.
Sensitivity and specificity for the first subtest (ultra-short form), the first two subtests (short form), and the total score of the BDST were obtained via receiver operating characteristic curves and compared with the sensitivity and specificity values of the Mini-Mental Status Examination (MMSE).
Results
The overall diagnostic quality of the BDST was superior to the MMSE for mild Alzheimer’s dementia (sensitivity and specificity = .94 (95% CI .92 to .96) and .82 (95% CI .75 to .88) vs. .79 (95% CI .76 to .83) and .88 (95% CI .82 to .93)) as well as for other subtypes of mild dementia (sensitivity and specificity = .91 (95% CI .88 to .94) and .82 (95% CI .75 to .88) vs. .72 (95% CI .67 to .76) and .88 (95% CI .82 to .93)). Even the short form of the BDST was comparable to the MMSE regarding sensitivity and specificity. For moderate dementia, it was possible to identify dementia cases with sufficient and excellent diagnostic quality by using the ultra-short and the short form.
Conclusions
The BDST is able to detect dementia in geriatric hospital settings. If the adaptive algorithm is used, administration time can be reduced to less than 2 min in most cases. Because no test materials have to be exchanged, this test is particularly suitable for infectious environments where contact between the examiner and the person being tested should be minimized.
(1) Background: Dementia and mild cognitive impairment (MCI) are still underdiagnosed in the general population. Impaired odor identification has been identified as an early marker of MCI and dementia. We aimed to compare the additional diagnostic value of two odor identification tests to a cognitive screening test in detecting MCI or dementia. (2) Methods: The Sniffin’ Sticks odor identification test (SS-OIT), a brief odor identification test (B-OIT) requiring the identification of coffee scent, and the Mini-Mental State Exam (MMSE) were administered to a consecutive series of 174 patients (93 with dementia, 42 with mild cognitive impairment, and 39 without cognitive impairment) referred for neuropsychological testing. (3) Results: Both participants with dementia and with MCI exhibited impairments in odor identification. The SS-OIT and the B-OIT were substantially correlated. Complementing MMSE scores with the SS-OIT or the B-OIT similarly improved the diagnostic accuracy of individuals with dementia and MCI. (4) Conclusions: People with suspected dementia or MCI may already benefit from brief odor identification tests. Although these tests require little additional time, they can notably increase sensitivity for dementia or MCI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.