Purpose To assess the agreement among four types of intraocular pressure (IOP) measurements: IOP obtained by Goldmann applanation tonometer (IOP-GAT),IOP obtained by an air-puff tonometer (Nidek NT-510)(IOP-NCT), the non-corrected IOP obtained by the Corneal Visualization Scheimpflug Technology (IOP-Corvis) and the biomechanically corrected IOP obtained by the Corvis ST (bIOP-Corvis) in healthy patients with a broad spectrum of IOP values. Methods: This prospective, observational study recruited 113 healthy individuals. Each patient underwent IOP evaluation via GAT, Nidek NT-510 and Corvis ST. Difference in mean in IOP readings was assessed by one-way repeated-measures analysis of variance (ANOVA).Tonometer intermethod agreement was assessed by the Bland-Altman method. The difference between the four IOP measurements was correlated against corneal (CCT) and age with Pearson’s correlation test. Results: IOP-Corvis showed the highest values (16.59 ± 3.08 mmHg),followed by IOP-NCT (16.05 ± 3.43 mmHg), IOP-GAT (15.62 ± 3.08 mmHg) and bIOP-Corvis (15.10 ± 2.67 mmHg).There were statistically significant differences in IOP measurements among all the ANOVA pairwise comparisons except between IOP-GAT and bIOP-Corvis ( p = 0.07),as well as between IOP-GAT and IOP-NCT ( p = 0.25). Bland Altman analysis revealed a notable bias (all p < 0.05) among IOP-GAT and bIOP-Corvis, IOP-GAT and IOP-Corvis, IOP-GAT and IOP-NCT, bIOP-Corvis and IOP-Corvis, bIOP-Corvis and IOP-NCT,IOP-Corvis and IOP-NCT of 0.51, −0.97, −0.43, −1.49, −0.95, 0.53 mmHg respectively. We observed a strong correlation of the difference between bIOP-Corvis and IOP-Corvis with CCT and patient age. Conclusion: Compared with GAT and Nidek NT-510, the Corvis-derived IOPs were recorded either the highest as IOP-Corvis or the lowest as bIOP-Corvis. Even if the differences among the tonometers were relatively small, the IOP values obtained with the Corvis ST, NCT and GAT were not interchangeable.
Demodex spp may cause blepharitis and palpebra skin lesions. Since eyelash demodicosis seems to be quite spreadable in the community, every patient with chronic non-diagnosed blepharitis should be examined for Demodex spp. Tea tree oil treatment may be an efficient and safe therapeutical choice against ocular demodicosis.
Haemangiopericytoma is a highly vascular tumour, which is a rare soft tissue lesion that may arise anywhere in the body, including the orbit. During its surgical resection, it is too friable for the surgeon to handle and it can bleed severely causing many problems to the surgeon. That is why many surgical approaches have been reported till now, aiming at total excision with minimal blood loss. In this case, total resection of an orbital haemangiopericytoma in a 61-year-old Caucasian woman, using an intraoperative 23G needle injection of 40% n-butyl-2-cyanoacrylate and 60% lipiodol, is presented. The lesion was directly injected under fluoroscopic visualization, after which it became firm enough to be surgically removed without significant bleeding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.