Even after decades of clinical use, our ability to quantify wear across total hip replacement implant surfaces is largely limited to single value measurements. The influence of patient factors on wear remains enigmatic. This pilot study for the development of three-dimensional laser micrometry (3DLM) introduces an easy, accurate means of 'mapping' and quantifying material removal. A three-dimensional laser micrometer was constructed using a laser micrometer having an accuracy of 0.5 microm. A 3D surface map is triangulated from a point cloud consisting of approximately 140,000 individual points. Comparison to a reference sphere determines radial wear over the entire surface. 3DLM was able to map and quantify fine scale surface features. Even for zirconia on relatively soft ultra-high molecular weight polyethylene, this technique maps the contributions of localized wear at the macroscopic level. The 0.5 microm (or greater) accuracy of these lasers allows us to image surfaces with a high degree of confidence. This analysis lends itself well to automation, and we anticipate that this advance will prove valuable in establishing that each head and cup combination emerging from a given clinical environment has unique wear patterns as observed in this trial data set.
PurposeTraditional balloon kyphoplasty (BK) is a common treatment for symptomatic vertebral compression fractures. The purpose of this study was to compare a novel vertebral augmentation technique, radiofrequency-targeted vertebral augmentation (RF-TVA), to BK for restoration of vertebral height, cavity creation, and polymethylmethacrylate (PMMA) delivery and interdigitation into the surrounding trabeculae.MethodsThis ex vivo biomechanical pilot study utilized 16 osteoporotic cadaveric vertebral bodies in a standardized fracture model to compare unipedicular RF-TVA (n = 8) to bipedicular BK (n = 8). Four specimens from each group were tested in loaded and unloaded conditions. All specimens were imaged, assessed for height restoration, and sectioned to observe PMMA distribution. A subset of specimens underwent computed tomography scanning to assess cavity creation and trabecular architecture prior to cement delivery.ResultsAnterior height restoration was greater with RF-TVA (median: 84%, interquartile range: 62%–95%) compared to BK (median: 69%, interquartile range: 60%–81%), although the difference did not achieve statistical significance (P = 0.16). Anterior height restoration was numerically greater under loaded (median: 70% versus 66%) and unloaded (median: 94% versus 77%) conditions with RF-TVA versus BK. RF-TVA produced more discrete cavities and less native trabecular destruction compared to marked trabecular destruction observed with BK. RF-TVA consistently showed a well-identified focal area of PMMA with an extensive peripheral zone of PMMA interdigitation, providing mechanical interlock into the adjacent intact trabecular matrix. In contrast, BK yielded little evidence of PMMA interdigitation beyond the boundaries created by the balloon tamp due to the crushed trabecular bone peripherally.ConclusionRF-TVA achieves favorable vertebral height restoration with targeted PMMA delivery and less trabecular destruction compared to BK. RF-TVA has potential clinical utility in the aging population with painful osteoporotic vertebral fracture.
SummaryThree types of hip skids and a Hohmann retractor technique were used to facilitate reduction of the prosthesis in cadaveric canine total hip replacement. The degree of damage to the femoral head was evaluated using scanning electron microscopy and optical profilometry. Standard metal and ME-92 coated metal hip skids caused severe regional scratching of the femoral head. Morphologically similar scratch patterns were also identified on femoral heads retrieved from clinical patients. Use of a plastic coated skid or the Hohmann retractor technique had no perceptible effect on surface finish, and therefore either method is acceptable in clinical practice. The use of metal hip skids cannot be recommended for hip reduction as the resultant pattern of femoral head scratching is likely to be associated with early and severe polyethylene wear.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.