Objectives: Bone-conducted vestibular evoked myogenic potentials (VEMPs) are tuned to have their maximum amplitude in response to tone bursts at or below 250 Hz. The low-frequency limitations of clinical bone vibrators have not been established for transient, tone burst stimuli at frequencies that are optimal for eliciting VEMPs. Design: Tone bursts with frequencies of 250 to 2000 Hz were delivered to B71 and B81 bone vibrators and their output was examined using an artificial mastoid. The lower-frequency limit of the transducers was evaluated by examining the spectral output of the bone vibrators. Maximum output levels were evaluated by measuring input–output functions across a range of stimulus levels. Results: Both the B71 and B81 could produce transient tone bursts with frequency as low as 400 Hz. However, tone bursts with frequencies of 250 and 315 Hz resulted in output with peak spectral energy at approximately 400 Hz. From 500 to 2000 Hz, maximum output levels within the linear range were between 120 and 128 dB peak force level. The newer B81 bone vibrator had a maximum output approximately 5 dB higher than the B71 at several frequencies. Conclusions: These findings demonstrate that both transducers can reach levels appropriate to elicit bone-conducted VEMPs, but the low-frequency limitations of these clinical bone vibrators limit tone burst frequency to approximately 400 Hz when attempting to stimulate the otolith organs via tone bursts.
Cervical vestibular evoked myogenic potentials (cVEMPs) are usually elicited by transient tonebursts, but when elicited by amplitude-modulated (AM) tones, they can provide new information about cVEMPs. Previous reports of cVEMPs elicited by AM tones, or AMcVEMPs, have not systematically examined the effects of tonic EMG activation on their response properties. Fourteen young, healthy female adults (ages 20-24) with clinically normal audiograms participated in this study. AMcVEMPs were elicited with bone-conducted 500 Hz tones amplitude modulated at a rate of 37 Hz and recorded for five different EMG targets ranging from 0 to 90 μV. Amplitude increased linearly as tonic EMG activation increased. Signal-to-noise ratio (SNR) was minimal at 0 μV, but robust and with equivalent values from 30 to 90 μV; phase coherence and EMG-corrected amplitude had findings similar to SNR across EMG target levels. Interaural asymmetry ratios for SNR and phase coherence were substantially lower than those for raw or corrected amplitude. AMcVEMP amplitude scaled with tonic EMG activation similar to transient cVEMPs. Signal-to-noise ratio, phase coherence, and EMG-corrected amplitude plateaued across a range of EMG values, suggesting that these properties of the response reach their maximum values at relatively low levels of EMG activation and that higher levels of EMG activation are not necessary to record robust AMcVEMPs.
Objective: A variety of stimulus delivery methods can elicit vestibular evoked myogenic potentials (VEMPs). The current study compared bone conduction (BC) cervical VEMPs (cVEMPs) across two different clinical bone vibrators. It was hypothesized that the B81 transducer would be more effective for producing larger BC-cVEMP peak to peak amplitudes due to its low-frequency advantages in pure-tone audiometry applications. Design: Twenty young adults under the age of 40 years with no reported history of hearing or balance disorders participated in the study. BC cVEMPs were elicited using two clinical bone transducers: the Radioear B71 bone vibrator and the Radioear B81 bone vibrator. Both transducers were calibrated using the acoustic method of calibration before data collection, and the linear dynamic range of the transducers was determined. Participants were asked to sit and match a fixed electromyography (EMG) target level of 100 µV, while BC cVEMPs were recorded using stimulus frequencies of 250, 500, and 750 Hz. Results: Statistically significant differences in raw amplitude at 250 and 750 Hz between the B71 and B81 were observed; the B71 produced larger peak to peak amplitudes over the B81. At 500 Hz, larger amplitudes were observed with the B71, but results were not statistically significant. The B71 produced significantly lower cVEMP thresholds at all three frequencies. Across both transducers, 500 Hz produced the largest peak to peak amplitude compared with 250 and 750 Hz. Peak to peak amplitude did not increase above 55 dB nHL for 250 and 500 Hz, but amplitude continued to increase at 750 Hz. Discussion: The present study found statistically significant differences in BC-cVEMP amplitude and threshold between the B71 and B81, but results were not what we hypothesized. In general, the B71 elicited larger BC-cVEMP amplitudes and lower thresholds compared with the B81. Additionally, 500 Hz was found to be the best frequency for both BC transducers, contrasting previous studies suggesting lower frequencies yield larger BC-cVEMP amplitudes. It is possible that these average differences could also be clinically significant when looking at individual amplitude differences. Larger peak to peak amplitudes at 500 Hz may be partially due to the underlying physical levels used in the current study, as well as the output spectra of the transducers, and may explain the larger response amplitudes observed at 500 Hz compared with 250 Hz.
Otolith organs of the balance system, the saccule and utricle, encode linear acceleration. Integrity of the saccule is commonly assessed using cervical vestibular evoked myogenic potentials (cVEMPs) arising from an inhibitory reflex along the vestibulospinal pathway. Conventional approaches to eliciting these responses use brief, transient sounds to elicit onset responses. Here we used long-duration amplitude-modulated (AM) tones to elicit cVEMPs (AMcVEMPs) and analyzed their spectral content for evidence of nonlinear processing consistent with known characteristics of vestibular hair cells. Twelve young adults (ages 21-25) with no hearing or vestibular pathologies participated in this study. AMcVEMPs were elicited by bone-conducted AM tones with a 500 Hz carrier frequency. Eighteen modulation frequencies were used between 7 and 403 Hz. All participants had robust distortion products at harmonics of the modulation frequency. Total harmonic distortion ranged from approximately 10 to 80%. AMcVEMPs contain harmonic distortion products consistent with vestibular hair cell nonlinearities, and this new approach to studying the otolith organs may provide a non-invasive, in vivo method to study nonlinearity of vestibular hair cells in humans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.