Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125 per thousand, an artificially enriched reference water (delta(18)O of +78.91 per thousand) and two barium sulfates (one depleted and one enriched in (18)O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material delta(18)O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 +/- 0.36 per thousand USGS 35 sodium nitrate+56.81 +/- 0.31 per thousand IAEA-NO-3 potassium nitrate+25.32 +/- 0.29 per thousand IAEA-601 benzoic acid+23.14 +/- 0.19 per thousand IAEA-SO-5 barium sulfate+12.13 +/- 0.33 per thousand NBS 127 barium sulfate+8.59 +/- 0.26 per thousand VSMOW2 water 0 per thousand IAEA-600 caffeine-3.48 +/- 0.53 per thousand IAEA-SO-6 barium sulfate-11.35 +/- 0.31 per thousand USGS 34 potassium nitrate-27.78 +/- 0.37 per thousand SLAP water-55.5 per thousand The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for delta(18)O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (delta(18)O) of nitrates, sulfates, or organic material should explicitly state in their reports the delta(18)O values of two or more internationally distributed nitrates (USGS 34, IAEA-NO-3, and USGS 35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the delta(18)O values at a later time should it become necessary.The high-temperature reduction technique for analyzing delta(18)O and delta(2)H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process. We developed a method of dating cremated bone by accelerator mass spectrometry (AMS), using this carbonate fraction. Here we present results for a variety of prehistoric sites and ages, showing a remarkable success rate for this method.
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ 2 H VSMOW-SLAP values from-210.8 to +397.0 mUr or ‰, for δ 13 C VPDB-LSVEC from-40.81 to +0.49 mUr, and for δ 15 N Air from-5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C 16 nalkanes, n-C 20-fatty acid methyl esters (FAMEs), glycines, and L-valines, together with polyethylene powder and string, one n-C 17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2 H-enriched vacuum oil. Eleven laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic calibrations against international primary measurement standards. The use of reference waters in silver tubes allowed direct calibration of δ 2 H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Due to exchangeable hydrogen, amino acid RMs currently are recommended only for carbon-and nitrogen-isotope measurements. Some amino acids contain 13 C and carbon-bound organic 2 Henrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
With the presented building blocks, we show how to assure a reliable and accurate isotope analysis for the DLW method, both for human and for animal applications. Although our measurements have been performed using isotope ratio mass spectrometry, most of the procedures are also useful for laser spectrometry.
ABSTRACT. In Groningen, all organic samples for accelerator mass spectrometry (AMS) are combusted in an automatic Elemental Analyzer, coupled to an Isotope Ratio Mass Spectrometer and Cryogenic Trapping System. The Gas Chromatographic (GC) column, part of the Elemental Analyzer system, appeared to be the main cause for memory effects. Therefore we modified the Elemental Analyzer, such that the trapped CO 2 no longer passed the GC column. Our system modification reduced the memory effect significantly, as shown by lower radiocarbon concentration values for anthracite backgrounds, and a much smaller spread in these values. Our modified system can perform up to 40 combustions unattended in about 6 hr.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.