The disposal of a glucose bolus was studied to identify glucose metabolism in patients with and without type 2 diabetes mellitus (T2DM) during their regular hemodialysis (HD) treatment. Methods: Plasma glucose, insulin, and c-peptide concentrations were measured during a 60 min observation phase following a rapid glucose infusion (0.5 g/kg dry weight). Glucose disposition and elimination rates were determined from kinetic analysis, and insulinogenic index was calculated. Insulin resistance (R HOMA ) was determined by homeostatic model assessment (HOMA). Results: 35 HD patients (14 with T2DM) distinguished by a higher age (median: 70 vs. 55 y, p < 0.01) in T2DM patients were studied. Glucose kinetic data showed only small differences between patients with or without T2DM, but as R HOMA measured in all patients increased, a larger fraction of glucose was removed by the extracorporeal system (r = 0.430, p = 0.01).One hour after glucose bolus injection the glucose level was not different from that before HD also in patients with T2DM (p = 0.115). Conclusions: The larger glucose amount recovered in dialysate in patients with increasing R HOMA indicates that impaired glucose disposal could be measured during HD using a non-invasive dialysis quantification approach without blood sampling. Glucose infusion during HD is safe also in patients with T2DM.
(1) Background: It was examined whether glucose-induced changes in the relative blood volume are suitable to identify subjects with and without type-2 diabetes mellitus (T2D) during hemodialysis. (2) Methods: The relative blood volume was continuously recorded during hemodialysis and perturbed by the infusion of glucose comparable to the dose used for intravenous glucose tolerance tests. Indices of glucose metabolism were determined by the homeostatic model assessment (HOMA). Body composition was measured by a bioimpedance analysis. The magnitude and the time course of hemodilution were described by a modified gamma variate model and five model parameters. (3) Results: A total of 34 subjects were studied, 14 with and 20 without T2D. The magnitude of the hemodilution and the selected model parameters correlated with measures of anthropometry, body mass index, absolute and relative fat mass, volume excess, baseline insulin concentration, and HOMA indices such as insulin resistance and glucose disposition in a continuous analysis, but were not different in a dichotomous analysis of patients with and without T2D. (4) Conclusions: Even though the parameters of the hemodilution curve were correlated with measures of impaired glucose metabolism and body composition, the distinction between subjects with and without T2D was not possible using glucose-induced changes in the relative blood volume during hemodialysis.
Background: The quality of autonomic blood pressure (BP) control can be assessed by the entropy of serial BP data. The aim of this study was to evaluate the effect of hemodialysis (HD) and glucose infusion (GI) on amplitude aware permutation entropy (AAPE) of hemodynamic variables during HD in chronic kidney disease patients with and without type-2 diabetes mellitus (DM). Methods: Twenty-one patients without DM (NDO) and ten with DM were studied. Thirty minutes after the start of HD, a 40% glucose solution was administered. Hemodynamic data were extracted from continuous recordings using the Portapres® system. Results: AAPE decreased during HD in all patients and all hemodynamic signals with the exception of AAPE of mean and diastolic BP in DM patients. GI led to an increase in AAPE for cardiac output in all patients, while AAPE for heart rate and ejection time increased only in DM studies, and AAPE for systolic, diastolic, and mean arterial pressure, as well as total peripheral resistance, increased only in NDO patients. Conclusions: The reduction in entropy during HD indicates impaired autonomic control in response to external perturbations. This state is partially reversed by the infusion of glucose with differences in central and peripheral responsiveness in DM and NDO patients.
PurposeRenal biopsy-related arteriovenous fistula (RB-AVF), although usually asymptomatic, may sometimes result in serious clinical implications. The aim of the study was to prospectively evaluate the incidence of RB-AVF in native kidneys, together with the assessment of hemodynamic characteristics and the impact of the histopathological results of biopsy.Methods The study included 138 patients (age 46.2 ± 15.2; 70 F, 68 M), who underwent percutaneous renal biopsy (PRB) of the native kidney. In all patients, 2D and color Doppler ultrasound was performed 24 h after PRB in order to exclude RB-AVF.ResultsBleeding complications in the form of hematomas were found in 136 patients (98.55 %), and 23 cases of RB-AVF were observed (16.67 %). RB-AVF group had an increased maximal hematoma diameter and reduced number of glomeruli in PRB. The segmental arteries supplying the fistulas are characterized by higher maximum flow velocity (FV) and a lower resistance index (RI) compared to the normal segmental arteries (difference 45.9 ± 20.0 cm/s and 0.252 ± 0.104, respectively). In the ROC analysis, RI ≤ 0.524 allowed to detect RB-AVF with a sensitivity of 91 % and specificity of 100 % (AUC 0.998, p < 0.001). In approximately 39 % of RB-AVF cases, 2D ultrasound detected a hyperechogenic ischemic area between the fistula and the renal capsule.ConclusionsArteriovenous fistula is a quite frequent complication of native renal biopsy and can cause ischemia in the renal parenchyma detected by ultrasound. The arteries supplying the fistula are characterized by an increased flow velocity and reduced resistance index.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.