Early detection of leprosy is key to reduce the ongoing transmission. Antibodies directed against M. leprae PGL-I represent a useful biomarker for detecting multibacillary (MB) patients. Since efficient leprosy diagnosis requires field-friendly test conditions, we evaluated two rapid lateral flow assays (LFA) for detection of Mycobacterium leprae-specific antibodies: the visual immunogold OnSite Leprosy Ab Rapid test [Gold-LFA] and the quantitative, luminescent up-converting phosphor anti-PGL-I test [UCP-LFA]. Test performance was assessed in independent cohorts originating from three endemic areas. In the Philippine cohort comprising patients with high bacillary indices (BI; average:4,9), 94%(n = 161) of MB patients were identified by UCP-LFA and 78%(n = 133) by Gold-LFA. In the Bangladeshi cohort, including mainly MB patients with low BI (average:1), 41%(n = 14) and 44%(n = 15) were detected by UCP-LFA and Gold-LFA, respectively. In the third cohort of schoolchildren from a leprosy hyperendemic region in Brazil, both tests detected 28%(n = 17) seropositivity. Both rapid tests corresponded well with BI(p < 0.0001), with a fairly higher sensitivity obtained with the UCP-LFA assay. However, due to the spectral character of leprosy, additional, cellular biomarkers are required to detect patients with low BIs. Therefore, the UCP-LFA platform, which allows multiplexing with differential biomarkers, offers more cutting-edge potential for diagnosis across the whole leprosy spectrum.
BackgroundTransmission of Mycobacterium leprae, the pathogen causing leprosy, is still persistent. To facilitate timely (prophylactic) treatment and reduce transmission it is vital to both early diagnose leprosy, and identify infected individuals lacking clinical symptoms. However, leprosy-specific biomarkers are limited, particularly for paucibacillary disease. Therefore, our objective was to identify new biomarkers for leprosy and assess their applicability in point-of-care (POC) tests.MethodsUsing multiplex-bead-arrays, 60 host-proteins were measured in a cross-sectional approach in 24-h whole blood assays (WBAs) collected in Bangladesh (79 patients; 54 contacts; 51 endemic controls (EC)). Next, 17 promising biomarkers were validated in WBAs of a separate cohort (55 patients; 27 EC). Finally, in a third cohort (36 patients; 20 EC), five candidate markers detectable in plasma were assessed for application in POC tests.FindingsThis study identified three new biomarkers for leprosy (ApoA1, IL-1Ra, S100A12), and confirmed five previously described biomarkers (CCL4, CRP, IL-10, IP-10, αPGL-I IgM). Overnight stimulation in WBAs provided increased specificity for leprosy and was required for IL-10, IL-1Ra and CCL4. The remaining five biomarkers were directly detectable in plasma, hence suitable for rapid POC tests. Indeed, lateral flow assays (LFAs) utilizing this five-marker profile detected both multi- and paucibacillary leprosy patients with variable immune responses.InterpretationApplication of novel host-biomarker profiles to rapid, quantitative LFAs improves leprosy diagnosis and allows POC testing in low-resource settings. This platform can thus aid diagnosis and classification of leprosy and also provides a tool to detect M.leprae infection in large-scale contact screening in the field.
Leprosy is a debilitating, infectious disease caused by Mycobacterium leprae. Despite the availability of multidrug therapy, transmission is unremitting. Thus, early identification of M. leprae infection is essential to reduce transmission. The immune response to M. leprae is determined by host genetics, resulting in paucibacillary (PB) and multibacillary (MB) leprosy associated with dominant cellular or humoral immunity, respectively. This spectral pathology of leprosy compels detection of immunity to M. leprae to be based on multiple, diverse biomarkers. In this study we have applied quantitative user friendly lateral flow assays (LFAs) for four immune markers (anti-PGL-I antibodies, IL-10, CCL4 and IP-10) for whole blood samples from a longitudinal BCG vaccination field-trial in Bangladesh. Different biomarker profiles, in contrast to single markers, distinguished M. leprae infected from non-infected test groups, patients from household contacts (HHC) and endemic controls (EC), or MB from PB patients. The test protocol presented in this study merging detection of innate, adaptive cellular as well as humoral immunity, thus provides a convenient tool to measure specific biomarker profiles for M. leprae infection and leprosy utilizing a field-friendly technology.
Leprosy remains persistently endemic in several low- or middle income countries. Transmission is still ongoing as indicated by the unabated rate of leprosy new case detection, illustrating the insufficiency of current prevention methods. Therefore, low-complexity tools suitable for large scale screening efforts to specifically detect M. leprae infection and diagnose disease are required. Previously, we showed that combined detection of cellular and humoral markers, using field-friendly lateral flow assays (LFAs), increased diagnostic potential for detecting leprosy in Bangladesh compared to antibody serology alone. In the current study we assessed the diagnostic performance of similar LFAs in three other geographical settings in Asia, Africa and South-America with different leprosy endemicity. Levels of anti-PGL-I IgM antibody (humoral immunity), IP-10, CCL4 and CRP (cellular immunity) were measured in blood collected from leprosy patients, household contacts and healthy controls from each area. Combined detection of these biomarkers significantly improved the diagnostic potential, particularly for paucibacillary leprosy in all three regions, in line with data obtained in Bangladesh. These data hold promise for the use of low-complexity, multibiomarker LFAs as universal tools for more accurate detection of M. leprae infection and different phenotypes of clinical leprosy.
Background The development of a fast and accurate, non-sputum-based point-of-care triage test for tuberculosis (TB) would have a major impact on combating the TB burden worldwide. A new fingerstick blood test has been developed by Cepheid (the Xpert-MTB-Host Response (HR)-Prototype), which generates a ‘TB score’ based on mRNA expression of 3 genes. Here we describe the first prospective findings of the MTB-HR prototype. Methods Fingerstick blood from adults presenting with symptoms compatible with TB in South Africa, The Gambia, Uganda and Vietnam was analysed using the Cepheid GeneXpert MTB-HR prototype. Accuracy of the Xpert MTB-HR cartridge was determined in relation to GeneXpert Ultra results and a composite microbiological score (GeneXpert Ultra and liquid culture) with patients classified as having TB or other respiratory diseases (ORD). Results When data from all sites (n=75 TB, 120 ORD) were analysed, the TB score discriminated between TB and ORD with an AUC of 0·94 (CI, 0·91-0·97), sensitivity of 87% (CI, 77-93%) and specificity of 94% (88-97%). When sensitivity was set at 90% for a triage test, specificity was 86% (CI, 75-97%). These results were not influenced by HIV status or geographical location. When evaluated against a composite microbiological score (n=80 TB, 111 ORD), the TB score was able to discriminate between TB and ORD with an AUC of 0·88 (CI, 0·83-0·94), 80% sensitivity (CI, 76-85%) and 94% specificity (CI, 91-96%). Conclusions Our interim data indicate the Cepheid MTB-HR cartridge reaches the minimal target product profile for a point of care triage test for TB using fingerstick blood, regardless of geographic area or HIV infection status.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.