This lay-led navigator service provided support to a group of unwell individuals, with few resources and multiple barriers to negotiate, and has effectively engaged with health and social care services, while overcoming various barriers and obstacles to its establishment and ongoing operation.
Background: The global SARS-CoV-2 (COVID-19) pandemic has caused substantial worldwide mortality. At present, there is no data regarding oncologist-specific SARS-CoV-2 infection/immunity rates in the United Kingdom (UK) which might impact planning for the management of potentially immunosuppressed cancer patients. Here, we present the first results from the COVID-19 Serology in Oncology Staff (CSOS) study with the aim of informing non-surgical oncology management guidelines. Methods: Patient-facing staff working in an oncology department during the COVID-19 pandemic at a large district general hospital in the East of England were invited to participate. Samples were collected during the first week of June 2020: blood for SARS-COV-2 antibody testing using a rapid lateral flow point of care (POC) assay and a laboratory Luminex based assay, as well as a nasopharyngeal swab for SARS-CoV-2 PCR testing. Participant characteristics were also collected. Results: Seventy participants were recruited: nurses (45/70; 64.3%), doctors (15/70; 21.2%), and other patient-facing staff (10/70; 14.3%). The majority were female (61/70; 87.1%) with a mean age of 42 years (median 41; range 23-64 years). A minority were smokers (9/70; 10%) or had chronic underlying health conditions (16/70; 22.9%), the commonest being asthma. All participants were nasopharyngeal-swab PCR negative, although 4/70 (5.7%) had previously tested positive by NHS testing undertaken during the preceding months. 15/70 (21.4%) had positive SARS-CoV-2 antibodies using the Luminex test. Nurses had the highest incidence of positive antibodies (13/45; 28.9%), with a lower incidence in doctors (2/15; 13.3%) although this difference was not statistically significant (Fischer's exact test p=0.3). No receptionists had positive antibody tests. All four participants with a previously reported positive PCR test were antibody-positive. 9/15 (60%) of antibody-positive participants reported previous symptoms suggestive of SARS-CoV-2 infection: a 3.6-fold higher odds than antibody-negative participants, of whom 16/55 reported symptoms (p=0.03). The mean duration of symptoms was 11 days (median 11; range 1-35 days) and the mean time from resolution of reported previous symptoms to antibody testing was 48.4 days (median 46; range 1-123 days). Conclusion: This study establishes the SARS-CoV-2 exposure and carriage rate amongst patient-facing staff working in the oncology department of a large UK general hospital during the pandemic. These results may help inform UK national oncology patient management prior to the development of a viable vaccine or treatment.
Aims: The proportion of UK oncology healthcare professionals (HCPs) infected with SARS-CoV-2 during the COVID-19 pandemic's first wave is unknown. The primary aim of this study was to determine the SARS-CoV-2 infection and seroprevalence rates among HCPs. Materials and methods: Patient-facing oncology HCPs working at three large UK hospitals during the COVID-19 pandemic's first wave underwent polymerase chain reaction (PCR) and antibody testing [Luminex and point-of-care (POC) tests] on two occasions 28 days apart (JuneeJuly 2020). Results: In total, 434 HCPs were recruited: nurses (58.3%), doctors (21.2%), radiographers (10.4%), administrators (10.1%); 26.3% reported prior symptoms suggestive of SARS-CoV-2. All participants were PCR negative during the study, but 18.4% were Luminex seropositive on day 1, of whom 42.5% were POC seropositive. Nurses had the highest seropositive prevalence trend (21.3%, P ¼ 0.2). Thirty-eight per cent of seropositive HCPs reported previous SARS-CoV-2 symptoms: 1.9 times higher odds than seronegative HCPs (P ¼ 0.01). Of 400 participants retested on day 28, 13.3% were Luminex seropositive (92.5% previously, 7.5% newly). Thirty-two per cent of initially seropositive HCPs were seronegative on day 28. Conclusion: In this large cohort of PCR-negative patient-facing oncology HCPs, almost one in five were SARS-CoV-2 antibody positive at the start of the pandemic's first wave. Our findings that one in three seropositive HCPs retested 28 days later became seronegative support regular SARS-CoV-2 PCR and antibody testing until widespread immunity is achieved by effective vaccination.
Background International guidelines for testing potentially immunosuppressed cancer patients receiving non-surgical anticancer therapies for SARS-CoV-2 (COVID-19) are currently lacking. The value of routinely testing staff treating cancer patients is not known. Methods: Patient-facing oncology department staff at work during the COVID-19 pandemic consented to have a nasopharyngeal swab SARS-CoV-2 antigen test by polymerase chain reaction (PCR) and blood tests for SARS-CoV-2 antibody using a laboratory Luminex-based assay and a rapid point-of-care (POC) assay on 2 occasions 28 days apart in June and July 2020. Results 434 participants were recruited: nurses (58.3%), doctors (21.2%), radiographers (10.4%) and administrators (10.1%). 82% were female; median age 40-years (range 19-66). 26.3% reported prior symptoms suggestive of SARS-CoV-2 infection and 1.4% tested PCR-positive prior to June 2020. All were PCR-negative at both study day 1 and 28. 18.4% were SARS-CoV-2 sero-positive on day 1 by Luminex, of whom 42.5% also tested positive by POC. 47.5% of Luminex sero-positives had antibodies to both nucleocapsid (N) and surface (S) antigens. Nurses (21.3%) and doctors (17.4%) had higher prevalence trends of Luminex sero-positivity compared with administrators (13.6%) and radiographers (8.9%) (p=0.2). 38% of sero-positive participants reported previous symptoms suggestive of SARS-CoV-2 infection, a 1.9-fold higher odds than sero-negative participants (p=0.01). 400 participants re-tested on day 28: 13.3% were Luminex sero-positive of whom 92.5% were previously positive and 7.5% newly positive. Nurses (16.5%) had the highest seroprevalence trend amongst staff groups (p=0.07). 32.5% of day 1 sero-positives became sero-negative by day 28: the majority being previously reactive to the N-antigen only (p<0.0001). Conclusion The high prevalence of SARS-CoV-2 IgG sero-positivity in oncology nurses, and the high decline of positivity over 4 weeks supports regular antigen and antibody testing in this staff group for SARS-CoV-2 as part of routine patient care prior to availability of a vaccine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.