A automação e supervisão de sistemas tem sido crescente, propiciando o aumento da comodidade e confiabilidade, bem como o reduzido gasto de processos. Vinculado a aplicativos web com interface amigável, os sistemas automatizados proporcionam a eficientização de sistemas elétricos de edificações com extrema praticidade. Após o desenvolvimento de um sistema de automação de baixo custo, este artigo apresenta o desenvolvimento de uma aplicação web capaz de gerenciar um sistema automatizado de iluminação elétrica a partir de diferentes dispositivos com acesso à internet. Como estudo de caso, o trabalho apresenta o impacto da automação associado ao aplicativo web no consumo e custo de energia elétrica de um edifício de uma instituição de ensino público.
Sympathetic inrush current phenomenon occurs when a transformer is switched on in a power network containing other transformers that are already energized. This interaction significantly changes duration and magnitude of transient magnetizing currents in the transformers involved and may lead to misoperation of these equipment. Therefore, in this paper it is presented the results of electromagnetic analysis due to sympathetic inrush and inrush current phenomenon among single-phase 50 MVA transformers in a power substation in the northern region of Brazil. For this purpose, the nine single-phase transformers installed at SE Guamá forming three three-phase banks, were modeled in the ATP software to obtain the energization behavior. In this paper the electromagnetic analyzes are performed in steady state, so only the first peak is used. In this way, results of the electromagnetic behavior of transformers are presented and compared sympathetic inrush with inrush current.
The main equipment responsible for connection and transmission of electric power from generating centers to consumers are power transformers. This type of equipment is subject to various types of faults that can affect its components, in some cases also compromising its operation and, consequently, the electric power supply. Thus, in this paper, electromagnetic, thermal, and structural analysis of power transformers was carried out with the objective of providing the operator with information on the ideal moment for performing predictive maintenance, avoiding unplanned shutdowns. For this, computational simulations were performed using the finite element method (FEM) and, from that, the different transformer operation ways, nominal currents, inrush current, and short-circuit current were analyzed. In this perspective, analyses of the effects that thermal expansion, axial forces, and radial forces exerted were carried out, contributing to possible defects in this type of equipment. As a study object, simulations were carried out on a 50 MVA single-phase transformer. It is important to emphasize that the simulations were validated with real data of measurements and with results presented in the current literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.