Medication reconciliation procedures are required to minimise medication discrepancies and enhance patient safety. Integration of patient health records across care levels is necessary but not sufficient to prevent errors.
We studied the quantification of an intact therapeutic monoclonal antibody (mAb), rituximab (RTX), using (reversephase) high-performance liquid chromatography with diode array detection ((RP)HPLC/DAD). To this end, we developed a chromatographic method and validated it as stabilityindicating in accordance with the International Conference on Harmonization guidelines (ICH). A 300-Å C8 column (250 mm×4.6 mm, 5 μm) was used to perform the analysis, and the temperature was maintained at 70 °C. Although only one mAb was analyzed, it was necessary to apply a gradient to elute it with a complex organic mixture. Chromatograms were registered at several wavelengths, with λ =214 nm employed for quantification purposes. The method was developed to quantify marketed RTX under typical hospital administration conditions. Further dilution was avoided in order to prevent additional mAb modification, and in this way the method was shown to be linear from 60 to 5000 mg/L. The precision of the method (repeatability and intermediate precision, estimated as the relative standard deviation, RSD %), was less than 1.0 %. Accuracy, specificity, robustness, and system suitability were also evaluated as specified in the ICH guidelines.We conducted a comprehensive chromatographic analysis by submitting RTX to several informative stress conditions. These forced degradation studies were conducted for two reasons: to estimate the specificity of the method, and to evaluate the robustness of the mAb formulation against external stress factors when handling it in preparation for administration. Thus, we investigated the effects of acid, base, oxidation, ionic strength, temperature, and UV light. Although a slight modification to the intact mAb could not be distinguished chromatographically in the stress studies we conducted, the procedure proposed here to evaluate peak purity enabled us to detect it with a satisfactory level of confidence. The proposed method could therefore be considered stability-indicating for quantyfying the intact mAb since it is qualified to detect its degradation/modification. Finally, the method was used to evaluate RTX in a long-term stability study performed under hospital conditions of use.
There was a high prevalence of REs among patients admitted to the surgical departments, most frequently the omission of a drug. The risk of an RE was higher in patients admitted for elective versus emergency surgery, as well as with the receipt of a larger number of drugs before admission.
The MBDS is a useful and accessible instrument to determine the incidence of ADR in a hospital, resulting in the notification of severe events that might otherwise not be reported. Its use also improves identification of the main drugs responsible for ADR and of the patient populations at greatest risk, facilitating the implementation of alert systems and the development of prevention and detection strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.