Neonatal jaundice is a common and severe disease in premature infants with Glucose-6-Phosphate Dehydrogenase (G-6-PD) deficiency. The World Health Organization (WHO) has recommended screening for G-6-PD deficiency in newborns for early recognition as well as to prevent unwanted outcomes in a timely manner. The present study aimed to assess a point-of-care, careSTARTTM G6PD biosensor as a quantitative method for the diagnosis of G-6-PD deficiency. Factors influencing the evaluation of G-6-PD enzyme activity were examined in 40 adults, including ethylenediaminetetraacetic acid (EDTA) anticoagulant, hematocrit concentration, storage temperature and time. Analytic performance of the careSTARTTM G6PD biosensor was evaluated in 216 newborns and compared with fluorescent spot test (FST) and standard quantitative G-6-PD enzyme activity (SGT) assay. The results of factors affecting the G-6-PD enzyme activity showed that the activity determined from finger-prick was not statistically different from venous blood (p = 0.152). The G-6-PD value was highly dependent on the hematocrit and rose with increasing hematocrit concentration. Its activity was stable at 4°C for 3 days. Reliability analysis between the careSTARTTM G6PD biosensor and SGT assay showed a strong correlation with a Pearson’s correlation coefficient of 0.82 and perfect agreement by intraclass correlation coefficient (ICC) of 0.90. Analysis of the area under the Receiver Operating Curve (AUC) illustrated that the careSTARTTM G6PD biosensor had 100% sensitivity, 96% specificity, 73% positive predictive value (PPV), 100% negative predictive value (NPV) and 97% accuracy at 30% of residual activity. While the diagnostic ability for identifying G-6-PD deficiency had 78% sensitivity, 89% specificity, 56% positive predictive value (PPV), 96% negative predictive value (NPV) and 88% accuracy when stratified by gender. The careSTARTTM G6PD biosensor is an attractive option as a point-of-care quantitative method for G-6-PD activity detection. Quantification of G-6-PD enzyme activity in newborns is the most effective approach for the management of G-6-PD deficiency to prevent severe jaundice and acute hemolysis.
Detection of α-thalassemia-1 (α-thal-1) carriers provides valuable insight for genetic consulting in prevention and control programs for couples who are at risk of conceiving a fetus with severe thalassemia, both Hb Bart's hydrops fetalis and hemolytic Hb H disease. The traditional method is complicated, time-consuming and requires high instrument cost and expertise. Loop-mediated isothermal amplification (LAMP) based on pH-sensitive dye technology, shows all the characteristics required of a real-time analysis with simple operation for potential use in the clinical diagnosis of high incidence α-thal-1 [Southeast Asian (SEA) or - - deletion]. Four primers specific for six distinct regions of the α-globin gene deletion were designed and analyzed by LAMP using the pH-indicator dye, phenol red. The amplification of the - - deletion changed the color of phenol red from pink to orange. The diagnostic ability of detection of the - - deletion by pH-sensitive LAMP was validated using both known and unknown blood samples and compared to the conventional polymerase chain reaction (PCR) method. Color inspection of pH-sensitive LAMP products could clearly identify the - - deletion. There was no cross reaction with a normal α-globin gene, α-thal-1 Thai (- - deletion), α-thal-2 [-α (rightward) and -α (leftward) deletion] and β-thalassemia (β-thal). Detection of the SEA deletion by pH-sensitive LAMP was consistent as compared to conventional PCR. The pH-sensitive LAMP method developed for this deletion carrier diagnosis has high sensitivity, specificity, simplicity, and requires simple instrumentation that makes it applicable for resource-limited laboratories in rural areas of developing countries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.