The ventilator, a life-saving device for COVID-19-infected patients, especially for pneumonia patients whose lungs are infected, has overwhelmingly skyrocketed since the pandemic of COVID-19 diseases started in December 2019. As a result, many biomedical engineers have rushed to design and construct emergency ventilators, using the Ambu-bag squeezing ventilator to compensate for the insufficient ventilators supply. The Ambu-bag squeezing ventilator, however, suffers from the limitation of delivered tidal volume to the patient, the setting respiration rate and the noisy operational sound due to the movement of mechanic parts. The Ambu-bag based ventilator is, hence, not suitable for prolonged treatment of the patient. This paper presents a design and construction of a blower-based pressure-controlled ventilator for home-treatment COVID-19 patients featured with our novel-designed flow and pressure sensor, electronic peep valve and proportional controlled valve. Our proposed ventilator can be programmed with the suitable parameter setting depending upon the weight, height, gender, and blood oxygen saturation (SpO2) of the patients. This is useful in the current situation of COVID-19 pandemics, where trained medical staff is limited. The designed ventilator is also equipped with a safety mechanism, including an excessive-pressure-release valve, excessive flow rate, overpressure, and over-temperature blower to prevent any hazardous event. A home ventilator server is also set where all ventilator parameters will be acquired and broadcasted for remote access of the health provider. The designed blower-based ventilator has been calibrated and evaluated with a lung simulator and standard ventilator tester, including alarmed functions, safety mechanism, sound level, and regulated pressure. The respiration output graph is complied with the simulation. The blower-based ventilator for home-treatment COVID-19 patients is suitable for life support, commensurate with the strict requirements of the FDA for life-support ventilators, and ready to be tested with animal subjects in the next phase.
This research concerns a design and construction of a bone mineral density (BMD) and bone mineral content (BMC) measurement system based on dual energy X-ray absorptiometry (DEXA). An indirect X-ray detector is designed by optical coupling CMOS sensor with image on the intensifying screen. A dedicated microcontroller X-ray apparatus is used as an X-ray source to capture two energy level X-ray of middle phalanges bone of middle finger. The captured image is processed based on modified Beer-Lambert law to compute bone mineral density. Bone mineral content is also computed by determining the area of the phalanges bone using active contour. The designed bone mineral density (BMD) and bone mineral content (BMC) measurement system is low-cost and hence can be distributed at district hospital for screening purposes of Osteoporosis of the elderly. Compared with BMD measured from commercial model, BMD measurement of our system acquires linear relation with R2 equals 0.969. The mean square error between the normalized BMD value and that of the commercial model is 0.0000981.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.