The effect of hydrostatic pressure on physiological intracoronary measurements is usually ignored in the daily clinical practice. Our aim was to investigate this effect on Pd/Pa (distal/aortic pressure) and FFR (fractional flow reserve). 41 FFR measurements between 0.7 and 0.9 were selected. The difference in the height of the orifice and that of the sensor was defined in mm on the basis of 3D coronary reconstruction. Resting Pd/Pa and FFR were adjusted by subtracting the hydrostatic pressure gradient from the distal pressure. Height measurements were also performed from 2D lateral projections for each coronary segment (n = 305). In case of the LAD, each segment was located higher (proximal:
In order to make optimal decisions on the treatment of atherosclerotic coronary heart disease (CHD), appropriate evaluation is necessary, including both the anatomical and physiological assessment of the coronary arteries. According to current guidelines, a fractional flow reserve (FFR)–based clinical decision is recommended, but coronary flow reserve (CFR) measurements and microvascular evaluation should also be considered in special cases for a detailed exploration of the coronary disease state. We aimed to generate an extended physiological evaluation during routine FFR measurement and define a new pathological flow–related prognostic factor. Fluid dynamic equations were applied to calculate CFR on the basis of the three-dimensional (3D) reconstruction of the invasively acquired coronary angiogram and the measured intracoronary pressure data. A new, potentially robust prognostic parameter of a coronary lesion called the “flow separation index” (FSi), which is thought to detect the pathological flow amount through a stenosis was introduced in a vessel-specific flow range. Correlations between FSi and the clinically established physiological indices (CFR and FFR) were determined. The FSi was calculated in 19 vessels of 16 patients, including data from the pre- and post-stent revascularization treatment of 3 patients. There was no significant correlation between the FSi and the CFR (r = −0.23, p = 0.34); however, there was significant negative correlation between the FSi and the FFR (r = −0.66, p = 0.002). An even stronger correlation was found between the FSi and the ratio of the resting pressure ratio and the FFR (r = 0.92, p < 0.0001). The diagnostic power of the FSi for predicting the FFR value of <0.80, as a gold standard prognostic factor, was tested by receiver operating characteristic analysis. FSi > 0.022 proved to be the cutoff value of the prediction of a pathologically low FFR with a 0.856 area under the curve (95% confidence interval: 0.620 to 0.972). The present flow–pressure–velocity display provides a comprehensive summary of patient-specific pathophysiology in CHD. The consequences of epicardial stenoses can be evaluated together with their complex relations to microvascular conditions. Based on these values, clinical decision-making concerning both pharmacological therapy and percutaneous or surgical revascularization may be more precisely guided.
Purpose: To develop a method of coronary flow reserve (CFR) calculation derived from three-dimensional (3D) coronary angiographic parameters and intracoronary pressure data during fractional flow reserve (FFR) measurement. Methods: Altogether 19 coronary arteries of 16 native and 3 stented vessels were reconstructed in 3D. The measured distal intracoronary pressures were corrected to the hydrostatic pressure based on the height differences between the levels of the vessel orifice and the sensor position. Classical fluid dynamic equations were applied to calculate the flow during the resting state and vasodilatation based on morphological data and intracoronary pressure values. 3D-derived coronary flow reserve (CFRp-3D) was defined as the ratio between the calculated hyperemic and the resting flow and was compared to the CFR values simultaneously measured by the Doppler sensor (CFRDoppler). Results: Haemodynamic calculations using the distal coronary pressures corrected for hydrostatic pressures showed a strong correlation between the individual CFRp-3D values and the CFRDoppler measurements (r = 0.89, p < 0.0001). Hydrostatic pressure correction increased the specificity of the method from 46.1% to 92.3% for predicting an abnormal CFRDoppler < 2. Conclusions: CFRp-3D calculation with hydrostatic pressure correction during FFR measurement facilitates a comprehensive hemodynamic assessment, supporting the complex evaluation of macro-and microvascular coronary artery disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.