The investigated collaborative eye health-care model led to a substantial improvement in appropriate referrals of glaucoma patients to ophthalmologists and could be suitable for optimizing patient care and utilization of resources. Improvement in follow-up of patients by optometrists is required to minimize inappropriately discontinued patient care.
To compare the visual fields results obtained using the Swedish interactive thresholding algorithm-Standard (SS) and the Swedish interactive thresholding algorithm-Faster (SFR) in normal subjects, glaucoma suspects, and patients with glaucoma and to quantify potential time-saving benefits of the SFR algorithm. DESIGN: Prospective, cross-sectional study. METHODS: One randomly selected eye from 364 patients (77 normal subjects, 178 glaucoma suspects, and 109 patients with glaucoma) seen in a single institution underwent testing using both SS and SFR on the Humphrey Field Analyzer. Cumulative test time using each algorithm was compared after accounting for different rates of test reliability. Pointwise and cluster analysis was performed to determine whether there were systematic differences between algorithms. RESULTS: Using SFR had a greater rate of unreliable results (29.3%) compared with SS (7.7%, P < .0001). This was mainly because of high false positive rates and seeding point errors. However, modeled test times showed that using SFR could obtain a greater number of reliable results within a shorter period of time. SFR resulted in higher sensitivity values (on average 0.5 dB for patients with glaucoma) that was greater under conditions of field loss (<19 dB). Cluster analysis showed no systematic patterns of sensitivity differences between algorithms. CONCLUSIONS: After accounting for different rates of test reliability, SFR can result in significant time savings compared with SS. Clinicians should be cognizant of false positive rates and seeding point errors as common sources of error for SFR. Results between algorithms are not directly interchangeable, especially if there is a visual field deficit <19 dB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.