Ceramic materials show excellent esthetic behavior, along with an absence of hypersensitivity, making them a possible alternative implant material in dental surgery. However, their surface properties enable only limited osseointegration compared to titanium implants. Within this study, a novel surface coating technique for enhanced osseointegration was investigated biologically and mechanically. Specimens of tetragonal zirconia polycrystal (TZP) and aluminum toughened zirconia (ATZ) were modified with glass solder matrices in two configurations which mainly consisted of SiO2, Al2O3, K2O, and Na2O. The influence on human osteoblastic and epithelial cell viability was examined by means of a WST-1 assay as well as live/dead staining. A C1CP-ELISA was carried out to verify procollagen type I production. Uncoated/sandblasted ceramic specimens and sandblasted titanium surfaces were investigated as a reference. Furthermore, mechanical investigations of bilaterally coated pellets were conducted with respect to surface roughness and adhesive strength of the different coatings. These tests could demonstrate a mechanically stable implant coating with glass solder matrices. The coated ceramic specimens show enhanced osteoblastic and partly epithelial viability and matrix production compared to the titanium control. Hence, the new glass solder matrix coating could improve bone cell growth as a prerequisite for enhanced osseointegration of ceramic implants.
Both titanium and ceramic materials provide specific advantages in dental implant technology. However, some problems, like hypersensitivity reactions, corrosion and mechanical failure, have been reported. Therefore, the combining of both materials to take advantage of their pros, while eliminating their respective cons, would be desirable. Hence, we introduced a new technique to bond titanium and ceramic materials by means of a silica-based glass ceramic solder. Cylindrical compound samples (Ø10 mm × 56 mm) made of alumina toughened zirconia (ATZ), as well as titanium grade 5, were bonded by glass solder on their end faces. As a control, a two-component adhesive glue was utilized. The samples were investigated without further treatment, after 30 and 90 days of storage in distilled water at room temperature, and after aging. All samples were subjected to quasi-static four-point-bending tests. We found that the glass solder bonding provided significantly higher bending strength than adhesive glue bonding. In contrast to the glued samples, the bending strength of the soldered samples remained unaltered by the storage and aging treatments. Scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analyses confirmed the presence of a stable solder-ceramic interface. Therefore, the glass solder technique represents a promising method for optimizing dental and orthopedic implant bondings.
Ceramics are a very popular material in dental implant technology due to their tribological properties, their biocompatibility and their esthetic appearance. However, their natural surface structure lacks the ability of proper osseointegration, which constitutes a crucial process for the stability and, thus, the functionality of a bone implant. We investigated the application of a glass solder matrix in three configurations-consisting mainly of SiO 2 , Al 2 O 3 , K 2 O and Na 2 O to TZP-A ceramic specimens. The corresponding adhesive strength and surface roughness of the coatings on ceramic specimens have been analyzed. Thereby, high adhesive strength (70.3 ± 7.9 MPa) was found for the three different coatings. The obtained roughness (R z ) amounted to 18.24 ± 2.48 µm in average, with significant differences between the glass solder configurations. Furthermore, one configuration was also tested after additional etching which did not lead to significant increase of surface roughness (19.37 ± 1.04 µm ) or adhesive strength (57.2 ± 5.8 MPa).In conclusion, coating with glass solder matrix seems to be a promising surface modification technique that may enable direct insertion of ceramic implants in dental and orthopaedic surgery.
In the field of dental technology, the length of ceramic pontics is limited to avoid mechanical failure. To reduce thermal-induced residual stress within the ceramic, using smaller subcomponents and subsequent bonding with silicate-based glass solder may be a favorable approach. Thus, the bending strength of zirconia compounds bonded with different silicate-based glass solders was investigated. For this purpose, rectangular specimens made of zirconia were bonded by glass solder. Parameters such as the scarf angle (45° and 90°), two different glass solders, as well as the soldering process (pressure and surface treatment) were varied. All specimens were subjected to quasi-static four-point bending tests according to DIN EN ISO 843-1. Additionally, the quality of the glass solder connection was evaluated using μCT and fractography. In the present study, zirconia compounds were sucessful bonded of zirconia compounds using silicate-based glass solder was. No significant differences in terms of bending strength were observed with respect to the different bonding parameters analyzed. The highest bending strength of 130.6 ± 50.5 MPa was achieved with a 90° scarf angle combined with ethanol treatment of the specimens before soldering and an additional application of a pressure of 2 bars in a dental pressure pot before subsequent soldering. Nevertheless, the bending strengths were highly decreased when compared to monolithic zirconia specimens (993.4 ± 125.5 MPa).
Purpose Zirconium dioxide ceramic has been successfully introduced as a framework material for fixed dental prostheses. To reduce manufacturing constraints, joining of subcomponents could be a promising approach to increase the mechanical performance of long‐span fixed dental prostheses. In this experimental study, the biomechanical behavior of monolithic and soldered framework specimens for fixed dental prostheses made of Y‐TZP was investigated. Materials and methods Framework specimens (n = 80) of 5‐unit fixed dental prostheses made of Y‐TZP were prepared and divided into 10 equal groups. The specimens were monolithic or composed of subcomponents, which were joined using a silicate‐based glass solder. Thereby, three joint geometries (diagonal, vertical with an occlusal cap, and dental attachment‐based) were investigated. Moreover, the groups differed based on the mechanical test (static vs. dynamic) and further processing (veneered vs. unveneered). The framework specimens were cemented on alumina‐based jaw models, where the canine and second molar were acting as abutments before a point‐load was applied. In addition, µCT scans and microscopic fractography were used to evaluate the quality of soldered joints and to determine the causes of fracture. Results The determined fracture loads of the different unveneered framework specimens in static testing did not vary significantly (p = 1). Adding a veneering layer significantly increased the mechanical strength for monolithic framework specimens from 1196.29 ± 203.79 N to 1606.85 ± 128.49 N (p = 0.008). In case of soldered specimens with a dental attachment‐based geometry, the mechanical strength increased from 1159.42 ± 85.65 N to 1249.53 ± 191.55 N (p = 1). Within the dynamic testing, no differences were observed between monolithic and soldered framework specimens. µCT scans and fractography proved that the dental attachment‐based joining geometry offers the highest quality. Conclusion Using glass soldering technology, subcomponents of 5‐unit framework specimens made of Y‐TZP could be joined with mechanical properties comparable to those of monolithic frameworks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.