Although good progress was made by two international benchmark exercises on in-plane permeability, existing methods have not yet been standardized. This paper presents the results of a third benchmark exercise using in-plane permeability measurement, based on systems applying the radial unsaturated injection method. 19 participants using 20 systems characterized a non-crimp and a woven fabric at three different fiber volume contents, using a commercially available silicone oil as impregnating fluid. They followed a detailed characterization procedure and also completed a questionnaire on their setup and analysis methods. Excluding outliers (2 of 20), the average coefficient of variation (c v) between the participant's results was 32% and 44% (non-crimp and woven fabric), while the average c v for individual participants was 8% and 12%, respectively. This indicates statistically significant variations between the measurement systems. Cavity deformation was identified as a major influence, besides fluid pressure/viscosity measurement, textile variations, and data analysis.
This paper reports the results of an international benchmark exercise on the measurement of fibre bed compaction behaviour. The aim was to identify aspects of the test method critical to obtain reliable results and to arrive at a recommended test procedure for fibre bed compaction measurements. A glass fibre 2/2 twill weave and a biaxial (±45°) glass fibre non-crimp fabric (NCF) were tested in dry and wet conditions.All participants used the same testing procedure but were allowed to use the testing frame, the fixture and sample geometry of their choice. The results showed a large scatter in the maximum compaction stress between participants at the given target thickness, with coefficients of variation ranging from 38 % to 58 %. Statistical analysis of data indicated that wetting of the specimen significantly affected the scatter in results for the woven fabric, but not for the NCF. This is related to the fibre mobility in the architectures in both fabrics. As isolating the effect of other test parameters on the results was not possible, no statistically significant effect of other test parameters could be proven. The high sensitivity of the recorded compaction pressure near the minimum specimen thickness to changes in specimen thickness suggests that small uncertainties in thickness can result in large variations in the maximum value of the compaction stress.Hence, it is suspected that the thickness measurement technique used may have an effect on the scatter.
Air-texturisation is a process that adds bulkiness to bundles of fibres. In this study, the permeability and compaction behaviour of air-texturised glass fibre rovings are experimentally characterised and compared to conventional unidirectional rovings. Based on radial impregnation experiments and single-step compaction/decompaction tests, the following main findings are highlighted: Compared to conventional unidirectional-rovings, the normalised permeability of the air-texturised rovings was approximately three times higher along the fibre direction and 40 times higher transverse to the fibre direction. Accordingly, the degree of anisotropy was approximately one magnitude lower. At a compaction pressure of 1 and 5 bar, the air-texturised rovings were compacted to a volume fraction of [Formula: see text] and 0.43, respectively, which was approximately 30% lower than the volume fraction achieved for the conventional unidirectional-rovings. Finally, it was observed that the decompaction of air-texturised rovings exhibits a more distinct elastic response when unloaded.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.