We report an unusual post-traumatic spinal cord herniation, which became symptomatic 38 years after the trauma. A 44-year-old man presented with a 2-year history of increasing impotence, neuropathic bladder dysfunction and dissociated sensory loss below the level of T6. At the age of 6 years he had a severe blunt spinal injury with transient paraparesis. MRI revealed right lateral and ventral displacement of the spinal cord at the T5/6 level. The spinal cord was surgically exposed and found to herniate through a ventral defect of the arachnoid membrane and the dura mater. As there were no other events that could have precipitated spinal cord herniation the reported blunt trauma in childhood is the most likely cause for the spinal cord herniation in this patient.
In the management of shunt infection, the use of ventricular catheters made of silicone rubber for the temporary external drainage of cerebrospinal fluid (CSF) is general practice. However, the eradication of the primary source of infection may be hindered by the affinity of bacteria to silicone-based material. Compared to silicone catheters, a metal drainage device for temporary ventriculostomy appears to offer more favourable conditions for successful eradication of the infection. Since metal needles cannot be implanted permanently and since their screw-type fixation precludes attachment to the skulls of infants or small children, we developed a flexible metal catheter. This catheter was used exclusively for the treatment of particularly serious or chronic infections of the CSF spaces. The catheter is made of implantation steel and consists of a corrugated tube that renders it flexible. Cerebrospinal fluid drains into a receptable bulb at the tip of the tube. Tubing of other materials may be connected to the end of the metal catheter for either external or internal drainage. It was implanted as a temporary and later permanent CSF drainage in 7 male patients aged from 4 to 60 years, who suffered from chronic, recurrent ventriculitis (n = 5) with an average of 7 previous surgical revisions, as well as from complex infections (n = 2; basal tuberculous meningitis, brain abscess). The infections were successfully eliminated in 6 patients. In the remaining patient, the metal catheter for external ventriculostomy had to be removed after 4 days due a leakage of CSF; it was replaced by a silicone catheter and later on by a needle drainage. Other complications, such as secondary infection or intracerebral haemorrhage, did not occur. The average duration of external CSF drainage via the flexible metal catheter was 27 days (range 4-50 days). In 4 patients, the CSF drainage was converted to a permanent ventriculoperitoneal shunt using a new flexible metal catheter. At the time of post-operative follow-up examination (average = 34 weeks), all shunts were functioning and there was no evidence of infection. In cases of especially complicated and protracted CSF infections, the flexible metal ventricular catheter is a promising device for treatment.
We report an unusual post-traumatic spinal cord herniation, which became symptomatic 38 years after the trauma. A 44-year-old man presented with a 2-year history of increasing impotence, neuropathic bladder dysfunction and dissociated sensory loss below the level of T6. At the age of 6 years he had a severe blunt spinal injury with transient paraparesis. MRI revealed right lateral and ventral displacement of the spinal cord at the T5/6 level. The spinal cord was surgically exposed and found to herniate through a ventral defect of the arachnoid membrane and the dura mater. As there were no other events that could have precipitated spinal cord herniation the reported blunt trauma in childhood is the most likely cause for the spinal cord herniation in this patient.
Intervertebral plates of hydroxy apatite ceramic (HAC) have been used in three patients for cervical vertebral interbody fusion after anterior discectomy. In one case a pure HAC "Disc" was used, which proved to be too friable. Specially designed intervertebral plates, which were composed of an HAC-coated core of alumina ceramic, were used in the other two cases. Clinically and radiologically optimal results after 1-year- and 2-year-follow-up suggest that HAC-ceramic might be a very promising material for vertebral interbody fusion. Possible complications and pain due to bone removal from the iliac crest are avoided, and the operative procedure is simplified.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.