Purpose: The purpose of this study was to design and characterize a custom HDR applicator for the treatment of cancers in the region 0–5 mm, comparing it to the dosimetric properties of the Maxima R‐100 superficial x‐ray unit. Accelerator produced electrons of energy 4–6 MeV with the addition of a buildup bolus are in competition with superficial X‐rays and are very well suited for the treatment of shallow lesions as the maximum dose, Dmax, is brought to the surface. With this applicator, HDR may be a modality suited for treatment of Basal and squamous cell carcinomas, Kaposi's sarcoma, and Merkel cell carcinomas. Method and Materials: The superficial machine was characterized in terms of percent depth dose, beam profiles, and dose rate. Similar measurements were taken from a Varian Varisource HDR unit applying a newly designed copper HDR applicator. Both data sets were compared in terms of dosimetric properties and clinical efficacy. Results: The applicator alone had an unacceptably large dose inhomogeneity across the the HDR beam so a primary filter, modified filter, and secondary lead collimator were designed and manufactured to help shape the dose into a profile similar to the superficial applicator. Beam flatness and width were nearly replicated but beam divergence was more pronounced for the HDR applicators. Conclusions: Percent depth dose measurements for the HDR applicator showed a dose fall‐off nearly identical to superficial x‐rays rather than the assumed inverse square dose fall‐off. Flatenning the HDR beam through this filtered applicator provides means to deliver uniform dose to surface lesions with superior treatment delivery while implementing the HDR billing codes.
In a mixed-vendor radiation oncology environment, it is advantageous if the department's treatment planning system (TPS) supports the linear accelerators of different vendors. In this publication beam data collection and modeling for the Versa HD linear accelerator in Monaco, Pinnacle, and Eclipse are discussed. In each TPS static field, Intensity-Modulated Radiation Therapy (IMRT) step and shoot, and Volumetric-Modulated Arc Therapy (VMAT) plans for flattened and flattening-filter free photon beams of all available energies were evaluated for field sizes >3 × 3. To compare passing rates, identical beam model validation plans were calculated in each TPS. Eclipse, Monaco, and Pinnacle beam models passed validation measurements in homogeneous materials for a variety of treatment fields, including static, IMRT, and VMAT. In the case of Eclipse, the "dosimetric leaf gap" parameter was found to be critical for passing rates of VMAT plans. The source size parameter plays an important role as well for small fields. In the case of Pinnacle the multileaf collimator offset table needed to be optimized for better VMAT QA results. Each of the investigated treatment planning systems met the criteria to be used clinically in conjunction with Elekta Versa HD linear accelerators. It can be of great advantage to have the option to operate a TPS and linear accelerator from different vendors, as decisions surrounding linear accelerator or TPS purchases are very complicated and not just limited to technical considerations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.