The aim of this study was to estimate radiation doses patients and staff are exposed to during interventional procedures (IPs), compare them with the international diagnostic reference levels and to develop initial National Diagnostic Reference Levels. The IP survey was undertaken as the initial task of which, retrospective data were collected from the only four Kenyan hospitals carrying out interventional radiology and cardiology procedures at the time of the study. Real-time measurement of radiation dose to patients and staff during these procedures was done. To the patients, kerma-area product (KAP) and fluoroscopy time measurements were done using an in-built KAP meter, while peak skin dose (PSD) was measured using slow Extended Dose Range (EDR2(®)) radiographic films. The staff occupational doses were measured using individual thermoluminescence dosemeters. The maximum and minimum KAP values were found to be 137.1 and 4.2 Gy cm(2), while the measured PSD values were 740 and 52 mGy, respectively. The fluoroscopic time range was between 3.3 and 70 min. The staff doses per procedure ranged between 0.05 and 1.41 mSv for medical doctors, 0.03 and 1.16 mSv for nurses, 0.04 and 0.78 mSv for radiographers and 0.04 and 0.88 mSv for clinical staff. The measured patient PSDs were within the threshold limit for skin injuries. However, with the current few IP specialists, an annual increase in workload as determined in the study will result in the International Commission on Radiation Protection annual eye lens dose limit being exceeded by 10 %. A concerted effort is required to contain these dose levels through use of protective gear, optimisation of practice and justification.
The objective of this study was to assess the level of compliance to quality assurance and image quality standards in computed tomography facilities in Kenyan hospitals. A quality assurance inspection and physical image quality assessment in eighteen representative computed tomography facilities were completed. A quantitative method was developed and used to score the results obtained from the physical image quality measurements using the American Association of Physicists in Medicine (AAPM) water phantom. Inspection was done in order to establish the level of compliance with internationally recognized standards such as those stipulated in the European Guidelines Quality Criteria for Computed Tomography and the International Basic Safety Standards for Protection against Ionizing Radiation. The overall findings placed the national quality management performance at 50±3%, while image quality and quality assurance performance were 61±3% and 37±3%, respectively. The quality assurance assessment benchmarked the country's level of quality management system compliance in diagnostic radiology. During accreditation appraisal, the scrutiny of scores from each stage in the medical imaging chain per facility will encourage continual implementation of the quality improvement process.PACS number: 87.57.C, 87.57.cf, 87.57.cj, 87.57.cm, 87.57.cp, 87.57.Q, 87.55.N
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.