Background-Atherosclerotic plaque rupture is usually a consequence of inflammatory cell activity within the plaque.Current imaging techniques provide anatomic data but no indication of plaque inflammation. The current "gold standard" imaging technique for atherosclerosis is x-ray contrast angiography, which provides high-resolution definition of the site and severity of luminal stenoses, but no information about plaque inflammation.There is a need to quantify plaque inflammation to predict the risk of plaque rupture and to monitor the effects of atheroma-modifying therapies. This is important because recent experimental and clinical studies strongly suggest that hepatic hydroxymethyl glutaryl coenzyme A reductase inhibitors (statins) promote plaque stability by decreasing plaque macrophage content and activity without substantially reducing plaque size and therefore angiographic appearance. 4 [ 18 F]-fluorodeoxyglucose ( 18 FDG) is a glucose analogue that is taken up by cells in proportion to their metabolic activity. 5 We tested the hypothesis that plaque inflammation could be visualized and quantified non-invasively using 18 FDG-PET in patients with symptomatic carotid artery disease.
Methods
Patient RecruitmentWe recruited 8 patients who had experienced a recent carotidterritory transient ischemic attack and had an internal carotid artery stenosis of at least 70%. Patients were excluded if they had either carotid artery occlusion or diabetes. The study protocol was approved by the local ethics committee and the UK Administration of Radioactive Substances Advisory Committee. All patients gave written informed consent.
PET ProtocolPET was carried out using a GE Advance PET scanner (GE Medical Systems). We administered 370 MBq 18 FDG intravenously over 60 seconds. PET images (as 4ϫ5 minute frames) were acquired in 3D mode, at 190 (Ϯ6) minutes after 18 FDG administration. This timepoint was chosen after preliminary dynamic studies indicated that late imaging provided optimal contrast between the 18 FDG concentration in plaque and the main background region, namely blood.A stiff cervical collar was worn to minimize patient movement. PET images were reconstructed using the 3D reprojection algorithm, 6 with corrections applied for attenuation, dead time, scatter, and random coincidences. Rigid body co-registration with CT was performed, using a combination of fiducial markers and internal anatomical landmarks (spinal cord and muscles of the jaw and neck). This resulted in co-registration typically to within 1 mm in each dimension around the stenosis. To estimate plaque 18 FDG concentration, three-dimensional volumes of interest (VOI) were drawn
CT ProtocolUsing a GE Hispeed Advantage CT scanner (GE Medical Systems), helical contrast CT angiograms were acquired from skull base to 3 cm below the level of the carotid bifurcation.
Plaque HistologyAfter imaging, carotid endarterectomy samples from all 8 patients imaged were fixed and stained with hematoxylin and eosin. Immunohistochemistry was performed using anti-macr...
The aim of this study was to establish whether or not to cement the hemiarthroplasty for displaced intracapsular femoral neck fractures in the elderly. Consecutive patients treated by hemiarthroplasty in adjacent hospitals were reviewed. The same monoblock prosthesis was used; in hospital A they were uncemented (121 patients), and in hospital B they were cemented (123 patients). Notes were reviewed retrospectively. Surviving patients (50 and 56 respectively) were assessed prospectively for pain and functional ability using validated scoring systems. Follow-up was 32-36 months. Patient demographics were similar. Fewer of the cemented group had been revised or were awaiting revision ( P=0.036). There was no difference in general complication or mortality rates. There was a highly statistically significant greater deterioration in pain ( P=0.003), walking ability ( P=0.002), use of walking aids ( P=0.003) and activities of daily living ( P=0.009) in the uncemented group. Our findings support the use of cemented hemiarthroplasty in the elderly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.