PurposeTo evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT.MethodsWe conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up.ResultsTwenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0–98.9) and 90.5% (95%CI: 69.6–98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6–97.3) and 86.4% (95%CI: 65.1–97.1), respectively.Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l.ConclusionsPreoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary hyperparathyroidism and negative or inconclusive conventional imaging results. Bilateral cervical exploration could be avoided in the majority (75%) of patients.
The present study provides the PET community with an EARL-compliant SUV as an independent prognosticator for advanced NSCLC that should be confirmed in a larger cohort, ideally at other EARL accredited centres, and highlights the need to harmonize PET quantitative metrics when using them for risk stratification of patients.
To seek for the minimal duration per bed position with a digital PET system without compromising image quality and lesion detection in patients requiring fast 18 F-FDG PET imaging. Materials and methods: 19 cancer patients experiencing pain or dyspnea and 9 pediatric patients were scanned on a Vereos system. List mode data were reconstructed with decreasing time frame down to 10 s per bed position. Noise was evaluated in the liver, blood pool and muscle, and using target-to-background ratios. Five PET readers recorded image quality, number of clinically relevant foci and of involved anatomical sites in reconstructions ranging from 60 to 10 s per bed position, compared to the standard 90 s reconstruction. Results: The following reconstructions, which harboured a noise not significantly higher than that of the standard reconstruction, were selected for clinical evaluation: 1iterations/10 subsets/20 sec (1i10 s20 sec ), 1i10 s30 sec , and 2i10 sPSF60 sec.Only the 60 s per bed acquisition displayed similar target-to-background ratios compared to the standard reconstruction, but mean ratios were still higher than 2.0 for the 30 s reconstruction. Inter-rater agreement for the number of involved anatomical sites and detected lesion was good or almost perfect (Kappa: 0.64−0.91) for all acquisitions. In particular, kappa for the 30 s per bed acquisition was 0.78 and 0.91 for lesion and anatomical sites number, respectively. Intra-rater agreement was also excellent for the 30 s reconstruction (kappa = 0.72). Median estimated total PET acquisition time for the 1i10 s30 sec , and the standard reconstruction were 4 and 12 min, respectively. Conclusions: Fast imaging is feasible with state-of-the-art PET systems. Acquisitions of 30 s per bed position are feasible with the Vereos system, requiring optimization of reconstruction parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.