Managing complex benign airway disease is a major challenge in interventional pulmonology. Airway stent placement can result in complications due to a variety of factors, including poor fit of the stent in the airway. We report the 1-year outcome of 2 patients with airway disease caused by granulomatosis with polyangiitis (Wegener’s) affecting the left main bronchus and secondary carina. These patients had not responded to systemic therapy or standard bronchoscopic techniques and had complications with commercially available airway stents. We describe a first-in-human, clinical experience to address these issues. Using computed tomography (CT) imaging and 3D printing technology, we generated and implanted patient-specific silicone airway stents to address airway disease. 3D patient-specific stent prescription was created using a CT scan of the patient’s chest and a proprietary software package originally developed for orthopedic surgical planning. Silicone stents were manufactured and implanted. Observation for > 1 year after implantation compared to the 6 months prior to patient-specific stent implant were compared for the number, clinically required stent changes, procedure time, and general clinical improvement per usual standard of care after airway stenting. Patients showed improved durability, a shorter procedure time, and improvement of patient-reported symptoms leading to a reduced need for stent changes and modifications. The use of 3D printing technology to make patient-specific silicone stents is feasible with early clinical proof of concept noting a durable improvement over 1 year of follow-up.
Our prediction rule can be used to estimate prN2/3 in patients with NSCLC. The model has the potential to facilitate clinical decision making in the staging of NSCLC.
This article describes the discovery of a chronic cervical wooden foreign body ventral to the left transverse processes of the cranial cervical spine using magnetic resonance imaging (MRI) in a dog that presented with chronic neck pain and lameness. The dog did not exhibit dysphagia or chronic draining tracts, the most common signs of the presumed cause, that of a penetrating oropharyngeal foreign body. The foreign body itself was represented on MR images as an oval straight-edged core within an inflammatory tissue reaction. The wood was slightly hyperintense on T2- and isointense on T1-weighted images relative to muscle. Surrounding this was a more conspicuous contrast-enhancing reactive tissue rim that was hyperintense on all pulse sequences. Adjacent musculature also exhibited diffuse edema and contrast enhancement that extended around the left cervical vertebral transverse processes and local intervertebral nerve roots. The foreign body was found to be a wooden stick upon surgical removal. MRI is an excellent method for visualizing the inflammatory tissue reactions associated with soft-tissue foreign bodies because of its contrast resolution and depiction of anatomy in multiple imaging planes.
Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy.Methods: A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up.Results: A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%).The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8-99.7%), 100% (95% CI, 92.1-100%), 97.8% (95% CI, 87.6-99.7%) and 98.2% (95% CI, 90.1-100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40-97.2%), 100% (95% CI, 86.8-100%), 92.9% (95% CI, 79.3-97.8%) and 94.3% (95% CI, 80.8-99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7).
Conclusions:The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.