Purpose:The aim of this study was to compare two methods of assessments of the coefficient of variation (COV) of endothelial cell area. Methods: A single image (Topcon SP-2000P specular microscope) was obtained from the central region of the corneal endothelium of 45 healthy white (Norwegian) individuals, aged from 24 to 43 years and without a history of major eye disease or surgery. The image file was printed to A3-size, the cell-cell boundaries marked manually and the areas of the cells measured with a digitiser pad. The same image file was independently processed by the semi-automated Topcon IMAGEnet system. From either method, the cell area data from 100 contiguous cells approximately in the middle portion of the images were used to calculate the average cell area (AVG), the coefficient of variation (COV) on the cell areas and the endothelial cell density (ECD). Results: Both methods produced similar AVG and ECD values that were not statistically different (p Ն 0.180). The SD values on the cell areas increased in relation to the AVG values (Pearson's r Ն 0.557). The resultant COV values were only marginally higher with the manual method (27.8 versus. 26.3 per cent) but the limits of agreement (LoA) for the COV values were rather large at -4.9 to +7.9 per cent. Conclusion: A semi-automated image analysis system can be used to generate COV data for the corneal endothelium similar to those of a manual method. The limits of agreement between the methods are substantial and this probably reflects the extreme sensitivity of the COV calculation to even a few different cell area values. This poor agreement needs to be considered in any comparative studies.
These studies confirm that the reproducibility (repeatability) of NCT and pachometry are substantially different. It is suggested that this aspect of tonometry needs to be taken into account, especially where there are lower values, when considering the possible impact of corneal thickness on tonometry measures and their interpretation. These types of effects need to be further assessed in older patients with ocular hypertension, or other glaucoma suspects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.