This paper presents a series of economic efficiency studies comparing three different investment variants: without energy storage, with energy stored in batteries and hydrogen installation with a PEM fuel cell stack for a location in Poland. To reach a target, the current solar potential in Poland, the photovoltaic (PV) productivity, the capacity of the energy storage in batteries as well as the size of the hydrogen production system were calculated. The solar potential was determined using archival meteorological data and the Krieg estimation method. A laboratory scale PV system (1 kW) was used to estimate the decrease in real solar installation power during the last 10 years of operation. All analyses were made for a 100 kW photovoltaic array located in Poland using static and dynamic methods of investment project assessment, such as Simply Bay Back Period (SPBP) or Net Present Value (NPV). The results showed that the SPBP amounted to 8.8 years and NPV 54,896 € for non-storage systems. Whereas, for systems with energy stored the economic indexes were, as follow: SPBP = never, NPV = 183,428 € for batteries and SPBP = 14.74 years, NPV = 22,639 € for hydrogen/fuel cell installation. Storage in hydrogen is more advantageous than batteries due to the smaller investment outlays.
This paper presents the results of a multifaceted analysis of the application of catalytic additives to hemp pellets’ combustion in a low-power boiler. The research concerns the effects of five catalytic additives applied inside the boiler’s combustion chamber—based on TiO2, MnO2, Cu(NO3)2 × 3H2O, H2PtCl6 solution, and 99.5% pure urea solution—on the quality of hemp pellets’ combustion process. For this purpose, technical and elemental analyses of the used fuel were performed. The chemical composition of exhaust gases (NOx, CO, SO2, and PM content) was also examined using an exhaust gas analyzer and a dust meter. The highest reductions in emissions of individual pollutants were for CO (−113%; combustion with Ad3), NOx (−66%; combustion with Ad 4), SO2 (−48%; combustion with Ad3), and PM (−78%; combustion with Ad1). The study also determined the amount of avoided costs due to the use of catalytic additives, as well as the annual prevented CO2 emissions to the atmosphere. Due to rising fuel and energy prices, this study could be helpful for biomass boiler owners who would like to burn locally available raw materials and increase the combustion process’ efficiency.
This paper presents the research results of the effect of using calcium oxide and potassium permanganate on the combustion of pellets from wheat bran and beet pulp. The measurements were performed in the technical laboratory of the Centre of Energy Utilization of Non-Traditional Energy Sources in Ostrava. The research examined the effect of the use of chemical substances on the amount of air pollutants from biomass thermal conversion in a low-power boiler and the process temperature. First, we performed technical and elementary analyses of agricultural waste. The raw material was then comminuted, mixed with a selected additive, pelletized, and finally burned in a low-power boiler. The additive was added in three proportions: 1:20, 1:10, and 1:6.67 (i.e., 15%) relative to the fuel weight. The combustion process efficiency was measured using a flue gas analyzer and three thermocouples attached to the data recorder. From the measurement results, we were able to determine the percentage reduction of pollutant emissions into the atmosphere (CO, NOx, and SO2) due to the use of additives. Because emission standards are becoming increasingly stringent and fuel and energy prices are rising, the results presented in this article may be useful to agri-food processing plants that want to manage these materials thermally.
The calculation method commonly used in the industry takes into consideration mainly fuel consumption (excluding electricity) and the amount of removed moisture which is reflected in the unit MJ·(Mg·%)−1. This is not a scientific approach because the result will change if the basic moisture is different (drying from 21% to 18% will consume less energy than drying from 18% to 15%). This paper aims to compare the energy consumption of two industrial continuous flow grain dryers powered by LPG and hard coal based on a comprehensive approach to energy efficiency calculation enriched with electricity consumption, flow measurements, and control of grain moisture. It could be useful for manufacturers who could use this method to generate more reliable data in their product datasheets, and it could also be legally regulated as an appropriate tool for calculating the energy consumption of agricultural grain dryers. According to the approach presented in this paper, the S428.CS construction powered by LPG gas had an energy consumption that was 6.14% lower than the DT2532 dryer construction, which used hard coal.
This paper presents the results of research on exhaust gases from landfill gas combustion. The measurements were carried out in a reclaimed landfill in Kiełcz (a passive degassing system based on gas flare). The research concerned the effects of selected exhaust gas purification technologies (platinum catalyzer on a ceramic carrier, molecular sieve, copper(II) oxide) for the quality of exhaust gases, and their particulate matter content. This paper aims to indicate which catalytic systems are most suitable for this gas type and their most efficient positioning in the flue gas duct. Due to increasingly stringent emission standards, the outcomes presented in this article could be helpful for landfill owners who wish to avoid paying fines for not complying with applicable limits. The measurements were carried out using a flue gas analyser, a particulate matter analyser fitted with a probe, and four thermocouples connected with the data recorder. The research outcomes determined the percentage reduction of pollutant emissions into the atmosphere (CO, NOx, and particulate matter) using catalysts. The potential benefits of using catalysts in landfill gas combustion systems due to their operating temperature ranges are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.