We report low temperature (T) optical spectra of the isolated CP47 antenna complex from Photosystem II (PSII) with a low-T fluorescence emission maximum near 695 nm and not, as previously reported, at 690-693 nm. The latter emission is suggested to result from three distinct bands: a lowest-state emission band near 695 nm (labeled F1) originating from the lowest-energy excitonic state A1 of intact complexes (located near 693 nm and characterized by very weak oscillator strength) as well as emission peaks near 691 nm (FT1) and 685 nm (FT2) originating from subpopulations of partly destabilized complexes. The observation of the F1 emission is in excellent agreement with the 695 nm emission observed in intact PSII cores and thylakoid membranes. We argue that the band near 684 nm previously observed in singlet-minus-triplet spectra originates from a subpopulation of partially destabilized complexes with lowest-energy traps located near 684 nm in absorption (referred to as AT2) giving rise to FT2 emission. It is demonstrated that varying contributions from the F1, FT1, and FT2 emission bands led to different maxima of fluorescence spectra reported in the literature. The fluorescence spectra are consistent with the zero-phonon hole action spectra obtained in absorption mode, the profiles of the nonresonantly burned holes as a function of fluence, as well as the fluorescence line-narrowed spectra obtained for the Q(y) band. The lowest Q(y) state in absorption band (A1) is characterized by an electron-phonon coupling with the Huang-Rhys factor S of approximately 1 and an inhomogeneous width of approximately 180 cm(-1). The mean phonon frequency of the A1 band is 20 cm(-1). In contrast to previous observations, intact isolated CP47 reveals negligible contribution from the triplet-bottleneck hole, i.e., the AT2 trap. It has been shown that Chls in intact CP47 are connected via efficient excitation energy transfer to the A1 trap near 693 nm and that the position of the fluorescence maximum depends on the burn fluence. That is, the 695 nm fluorescence maximum shifts blue with increasing fluence, in agreement with nonresonant hole burned spectra. The above findings provide important constraints and parameters for future excitonic calculations, which in turn should offer new insight into the excitonic structure and composition of low-energy absorption traps.
In the recent SARS-CoV-2 pandemic, public health experts have emphasized testing, tracking infected people, and tracing their contacts as an effective strategy to reduce the spread of the virus. Several diagnostic methods are reported for detecting the coronavirus in clinical, research, and public health laboratories. Some tests detect the infection directly by detecting the viral RNA and other tests detect the infection indirectly by detecting the host antibodies. A diagnostic test during the pandemic should help make an appropriate clinical decision in a short period of time. Recently reported diagnostic methods for SARS-CoV-2 have varying throughput, batching capacity, requirement of infrastructure setting, analytical performance, and turnaround times ranging from a few minutes to several hours. These factors should be considered while selecting a reliable and rapid diagnostic method to help make an appropriate decision and prompt public health interventions. This paper reviews recent SARS-CoV-2 diagnostic methods published in journals and reports released by regulatory agencies. We compared the analytical efficiency including limit of detection, sensitivity, specificity, and throughput. In addition, we also looked into ease of use, affordability, and availability of accessories. Finally, we discuss the limitations of the methods and provide our perspectives on priorities for future test development.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.