We propose and demonstrate an all-fiber passively mode-locked laser with a figure-8 cavity, which generates pulsed cylindrical vector beam output based on a mode selective coupler (MSC). The MSC made of a two mode fiber and a standard single mode fiber is used as both the intracavity transverse mode converter and mode splitter with a low insertion loss of about 0.65 dB. The slope efficiency of the fiber laser is > 3%. Through adjusting the polarization state in the laser cavity, both radially and azimuthally polarized beams have been obtained with high mode purity which are measured to be > 94%. The laser operates at 1556.3 nm with a spectral bandwidth of 3.2 nm. The mode-locked pulses have duration of 17 ns and a repetition rate of 0.66 MHz.
A new charge-coupled device (CCD) spectrometer has been studied and constructed by using a two-dimensional CCD detector and an integrated grating consisting of 10 subgratings. Effective spectral images of 268 mm along the dispersion direction have been densely folded 10 times to cover the full 200-1000 nm working wavelength range without any mechanical moving elements. The results show that the system has a spectral resolution and acquisition time of better than 0.07 nm and less than 100 ms, respectively, in the entire spectral range after system calibration.
This paper proposes a rapid method to detect aero-engine blade form, according to the characteristics of an aero-engine blade surface. This method first deduces an inclination error model in free-form surface measurements based on the non-contact laser triangulation principle. Then a four-coordinate measuring system was independently developed, a special fixture was designed according to the blade shape features, and a fast measurement of the blade features path was planned. Finally, by using the inclination error model for correction of acquired data, the measurement error that was caused by tilt form is compensated. As a result the measurement accuracy of the Laser Displacement Sensor was less than 10 μm. After the experimental verification, this method makes full use of optical non-contact measurement fast speed, high precision and wide measuring range of features. Using a standard gauge block as a measurement reference, the coordinate system conversion data is simple and practical. It not only improves the measurement accuracy of the blade surface, but also its measurement efficiency. Therefore, this method increases the value of the measurement of complex surfaces.
We demonstrate a scheme for long-range, high-precision absolute distance measurement based on frequency detection using two optoelectronic oscillators to convert distance information to frequency information. The two-oscillator design offers the unique advantage of self-referencing. By taking advantage of the accumulative magnification theory, the error of the measured distance is decreased by approximately 10⁵ fold, which significantly improves the precision of the measured distance. In our experiments, the maximum error is ±1.5 μm at an emulated distance of approximately 3.35 km, including a drift error of approximately 1 μm in the air path due to the variation of environmental conditions. The highest relative measurement precision achieved in our current system is 4.5×10⁻¹⁰.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.