Technology of shield tunneling has been widely used in modern city subway system building, however, due to the limit of urban construction land resources, it is inevitable for the new building structures conflicted with existing one. Thus, it is essential to taking correct measures to guarantee the safety of existing structure. In this case, a typical case of metro shield tunnel crossing through city overpass bridge piles underpinning construction project is studied by the numerical method and site field monitoring. According to the existing overpass bridge structure, geological conditions and site operation environment, a suitable construction method of piles foundation underpinning plan for this project is adopted. In order to ensure the structure safety of the existed overpass bridge during the pile foundation underpinning construction, a numerical simulation model is established which takes the whole foundation underpinning structure and construction steps into consideration. The numerical simulation result shows that the stress and the settlement of the piles foundation underpinning structure is reasonable. After the comparing of the site monitoring data with the numerical model simulation results, it is found that the site settlement and stress results are highly consistent with the calculated results, and it proves the feasibility of the piles foundation underpinning construction scheme. Eventually, the site gauging settlement data of the overpass pier and the pile cap indicate that the original overpass structure is barely affected by the shield tunnel construction, the construction method can provide reference and experience for the future similar projects.
The mechanical behavior of the steel–concrete joints in a composite bridge was investigated. Pull-out tests on eight specimens were carried out to evaluate the connection performance of Perfobond rib shear connectors (PBL shear connectors). In addition, static load tests were conducted on three composite joint specimens with a scale of 1/2 in a composite truss bridge. The crack load, load–displacement curves, strain distribution, and the joint stiffness were obtained from the composite joint to analyze the mechanical behavior of steel–concrete joints. The experimental results show that the embedded depth plays an important role in the ultimate bearing capacity and the deformation of PBL shear connectors and could even change the failure mode. Based on the test results of composite joints, the displacement increased almost linearly with the horizontal load on the concrete chord. There was no evident failure, and large deformation occurred in composite joints. In addition, the ultimate loads obtained from three composite joint specimens were greater than 2.93 times the design load (2050 kN). These investigated composite joints had excellent bearing capacity (above 6000 kN). This study will provide an experimental reference for the design of steel–concrete joints for composite truss bridges.
When a train crosses a bridge in a crosswind environment, the coupled vibration problem of the train-bridge system becomes prominent, and train safety and riding comfort are difficult to guarantee. Therefore, using the Pingtan Strait bridge in China as a case study, a co-simulation platform for the train-bridge system coupled vibration in crosswind environments was established based on computational fluid dynamics, finite element method, and the multi-body system dynamics. Based on this platform, dynamic response analysis of the train-bridge system was performed at different wind and train speeds. The results indicate that the dynamic response of the train and bridge under double-line conditions is greater than that under single-line conditions. With an increase in wind speed, the mid-span vertical displacement of the bridge changes little, while the lateral displacement increases significantly. Meanwhile, with increasing wind and train speeds, the train dynamic indexes obviously increase. Moreover, the dynamic index of the head car is the largest among all the train sections.
The core part of a hybrid truss bridge is the connection joint which combines the concrete chord and steel truss-web members. To study the mechanical behavior and failure mode of steel–concrete connection joints in a hybrid truss bridge, static model tests were carried out on two connection joints with the scale of 1:3 under the horizontal load which was provided by a loading jack mounted on the vertical reaction wall. The specimen design, experimental setup and testing procedure were introduced. In the experiment, the displacement, strain level, concrete crack and experimental phenomena were factually recorded. Compared with the previous study results, the experimental results in this study demonstrated that the connection joints had the excellent bearing capacity and deformability. The minimum ultimate load and displacement of the two connection joints were 5200 kN and 59.01 mm, respectively. Moreover, the connection joints exhibited multiple failure modes, including the fracture of gusset plates, the slippage of high-strength bolts, the local buckling of compressive splice plates, the fracture of tensile splice plates and concrete cracking. Additionally, the strain distribution of the steel–concrete connection joints followed certain rules. It is expected that the findings from this paper may provide a reference for the design and construction of steel–concrete connection joints in hybrid truss bridges.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.