Melatonin plays multiple physiological roles in the human body. Evaluation of melatonin production by the determination of urinary 6-sulfatoxymelatonin in 24-h samples has important drawbacks which hinder the successful evaluation of melatonin production in large cohorts. Here, we evaluated the potential of nail analysis for estimating melatonin production. Firstly, mass spectrometry methodology for the determination of melatonin in nails was optimized and successfully validated. The method was found to be linear in the range 6.5–830 fg/mg with intraday and interday accuracy in the range 100–104 %, precision below 15 % and a LOD of 3.5 fg/mg. Secondly, nail melatonin concentrations from 84 volunteers (age 5–96) were determined. The expected correlation between melatonin and age was obtained (correlation coefficient −0.615; p < 0.001). Additionally, we showed that fingernails are preferable to toenails to determine nail melatonin content. Finally, fingernails collected for 180 days after melatonin administration (two volunteers, 1.9 mg/night during 5 days) were analyzed. Nail melatonin concentrations immediately rose after administration and went back to pre-administration values after ≈100 days in both volunteers. Our results suggest that melatonin determination in nails is a suitable non-invasive tool for the estimation of global melatonin production. Due to the easy collection and storage of nails, the long-term information obtained and the multiple functions of melatonin, nail melatonin content might complement dim light melatonin onset, which is commonly measured from plasma/saliva samples, paving the way for melatonin research.
AimsHyponatraemia is the most common body fluid disorders but often goes unnoticed. Our laboratory incorporated a standardised procedure to help clinicians detect moderate/severe hyponatraemia. The study aims were to evaluate the outcomes on patient care and clinicians’ satisfaction.MethodsThe study, observational and retrospective, included 1839 cases, adult and paediatric patients, with sodium concentration <130 mmol/L. The procedure consisted of interpretative comments in the emergency and core laboratories report and the point-of-care testing blood gas network report. We evaluated hyponatraemia length in two equal periods: before and after the implementation. We conducted a survey addressed to the staff of the clinical settings involved to know their satisfaction.ResultsThe median hyponatraemia length decreased significantly from 4.95 hours (2.08–16.57) in the first period to 2.17 hours (1.06–5.39) in the second period. The lack of hyponatraemia patients follow-up was significantly less after the procedure implementation. The survey was answered by 92 (60 senior specialists and 32 residents) out of 110 clinicians surveyed. Ninety of them (98%) answered positively.ConclusionsWe have demonstrated the reduction in the time for diagnosing and management by physicians, the higher uniformity in the time required to solve hyponatraemia episodes following our laboratory procedure and the clinicians’ satisfaction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.