Occupational exposure modeling is widely used in the context of the E.U. regulation on the registration, evaluation, authorization, and restriction of chemicals (REACH). First tier tools, such as European Centre for Ecotoxicology and TOxicology of Chemicals (ECETOC) targeted risk assessment (TRA) or Stoffenmanager, are used to screen a wide range of substances. Those of concern are investigated further using second tier tools, e.g., Advanced REACH Tool (ART). Local sensitivity analysis (SA) methods are used here to determine dominant factors for three models commonly used within the REACH framework: ECETOC TRA v3, Stoffenmanager 4.5, and ART 1.5. Based on the results of the SA, the robustness of the models is assessed. For ECETOC, the process category (PROC) is the most important factor. A failure to identify the correct PROC has severe consequences for the exposure estimate. Stoffenmanager is the most balanced model and decision making uncertainties in one modifying factor are less severe in Stoffenmanager. ART requires a careful evaluation of the decisions in the source compartment since it constitutes ∼75% of the total exposure range, which corresponds to an exposure estimate of 20-22 orders of magnitude. Our results indicate that there is a trade off between accuracy and precision of the models. Previous studies suggested that ART may lead to more accurate results in well-documented exposure situations. However, the choice of the adequate model should ultimately be determined by the quality of the available exposure data: if the practitioner is uncertain concerning two or more decisions in the entry parameters, Stoffenmanager may be more robust than ART.
Occupational exposure models vary significantly in their complexity, purpose, and the level of expertise required from the user. Different parameters in the same model may lead to different exposure estimates for the same exposure situation. This paper presents a tool developed to deal with this concern-TREXMO or TRanslation of EXposure MOdels. TREXMO integrates six commonly used occupational exposure models, namely, ART v.1.5, STOFFENMANAGER(®) v.5.1, ECETOC TRA v.3, MEASE v.1.02.01, EMKG-EXPO-TOOL, and EASE v.2.0. By enabling a semi-automatic translation between the parameters of these six models, TREXMO facilitates their simultaneous use. For a given exposure situation, defined by a set of parameters in one of the models, TREXMO provides the user with the most appropriate parameters to use in the other exposure models. Results showed that, once an exposure situation and parameters were set in ART, TREXMO reduced the number of possible outcomes in the other models by 1-4 orders of magnitude. The tool should manage to reduce the uncertain entry or selection of parameters in the six models, improve between-user reliability, and reduce the time required for running several models for a given exposure situation. In addition to these advantages, registrants of chemicals and authorities should benefit from more reliable exposure estimates for the risk characterization of dangerous chemicals under Regulation, Evaluation, Authorisation and restriction of CHemicals (REACH).
Several occupational exposure models are recommended under the EU's REACH legislation. Due to limited availability of high-quality exposure data, their validation is an ongoing process. It was shown, however, that different models may calculate significantly different estimates and thus lead to potentially dangerous conclusions about chemical risk. In this paper, the between-model translation rules defined in TREXMO were used to generate 319000 different in silico exposure situations in ART, Stoffenmanager, and ECETOC TRA v3. The three models' estimates were computed and the correlation and consistency between them were investigated. The best correlated pair was Stoffenmanager-ART (R, 0.52-0.90), whereas the ART-TRA and Stoffenmanager-TRA correlations were either lower (R, 0.36-0.69) or no correlation was found. Consistency varied significantly according to different exposure types (e.g. vapour versus dust) or settings (near-field versus far-field and indoors versus outdoors). The percentages of generated situations for which estimates differed by more than a factor of 100 ranged from 14 to 97%, 37 to 99%, and 1 to 68% for Stoffenmanager-ART, TRA-ART, and TRA-Stoffenmanager, respectively. Overall, the models were more consistent for vapours than for dusts and solids, near-fields than for far-fields, and indoor than for outdoor exposure. Multiple linear regression analyses evidenced the relationship between the models' parameters and the relative differences between the models' predictions. The relative difference can be used to estimate the consistency between the models. Furthermore, the study showed that the tiered approach is not generally applicable to all exposure situations. These findings emphasize the need for a multiple-model approach to assessing critical exposure scenarios under REACH. Moreover, in combination with occupational exposure measurements, they might also be used for future studies to improve prediction accuracy.
Stoffenmanager®v4.5 and Advanced REACH Tool (ART) v1.5, two higher tier exposure assessment tools for use under REACH, were evaluated by determining accuracy and robustness. A total of 282 exposure measurements from 51 exposure situations (ESs) were collected and categorized by exposure category. In this study, only the results of liquids with vapor pressure (VP) > 10 Pa category having a sufficient number of exposure measurements (n = 251 with 42 ESs) were utilized. In addition, the results were presented by handling/activity description and input parameters for the same exposure category. It should be noted that the performance results of Stoffenmanager and ART in this study cannot be directly compared for some ESs because ART allows a combination of up to four subtasks (and nonexposed periods) to be included, whereas the database for Stoffenmanager, separately developed under the permission of the legal owner of Stoffenmanager, permits the use of only one task to predict exposure estimates. Thus, it would be most appropriate to compare full-shift measurements against ART predictions (full shift including nonexposed periods) and task-based measurements against task-based Stoffenmanager predictions. For liquids with VP > 10 Pa category, Stoffenmanager®v4.5 appeared to be reasonably accurate and robust when predicting exposures [percentage of measurements exceeding the tool’s 90th percentile estimate (%M > T) was 15%]. Areas that could potentially be improved include ESs involving the task of handling of liquids on large surfaces or large work pieces, allocation of high and medium VP inputs, and absence of local exhaust ventilation input. Although the ART’s median predictions appeared to be reasonably accurate for liquids with VP > 10 Pa, the %M > T for the 90th percentile estimates was 41%, indicating that variance in exposure levels is underestimated by ART. The %M > T using the estimates of the upper value of 90% confidence interval (CI) of the 90th percentile estimate (UCI90) was considerably reduced to 18% for liquids with VP > 10 Pa. On the basis of this observation, users might be to consider using the upper limit value of 90% CI of the 90th percentile estimate for predicting reasonable worst case situations. Nevertheless, for some activities and input parameters, ART still shows areas to be improved. Hence, it is suggested that ART developers review the assumptions in relation to exposure variability within the tool, toward improving the tool performance in estimating percentile exposure levels. In addition, for both tools, only some handling/activity descriptions and input parameters were considered. Thus, further validation studies are still necessary.
The Advanced REACH Tool (ART) is the most sophisticated tool used for evaluating exposure levels under the European Union's Registration, Evaluation, Authorisation and restriction of CHemicals (REACH) regulations. ART provides estimates at different percentiles of exposure and within different confidence intervals (CIs). However, its performance has only been tested on a limited number of exposure data. The present study compares ART's estimates with exposure measurements collected over many years in Switzerland. Measurements from 584 cases of exposure to vapours, mists, powders, and abrasive dusts (wood/stone and metal) were extracted from a Swiss database. The corresponding exposures at the 50th and 90th percentiles were calculated in ART. To characterize the model's performance, the 90% CI of the estimates was considered. ART's performance at the 50th percentile was only found to be insufficiently conservative with regard to exposure to wood/stone dusts, whereas the 90th percentile showed sufficient conservatism for all the types of exposure processed. However, a trend was observed with the residuals, where ART overestimated lower exposures and underestimated higher ones. The median was more precise, however, and the majority (≥60%) of real-world measurements were within a factor of 10 from ART's estimates. We provide recommendations based on the results and suggest further, more comprehensive, investigations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.