Sensitive detection of acetone and hydrogen sulfide levels in exhaled human breath, serving as breath markers for some diseases such as diabetes and halitosis, may offer useful information for early diagnosis of these diseases. Exhaled breath analyzers using semiconductor metal oxide (SMO) gas sensors have attracted much attention because they offer low cost fabrication, miniaturization, and integration into portable devices for noninvasive medical diagnosis. However, SMO gas sensors often display cross sensitivity to interfering species. Therefore, selective real-time detection of specific disease markers is a major challenge that must be overcome to ensure reliable breath analysis. In this work, we report on highly sensitive and selective acetone and hydrogen sulfide detection achieved by sensitizing electrospun SnO2 nanofibers with reduced graphene oxide (RGO) nanosheets. SnO2 nanofibers mixed with a small amount (0.01 wt %) of RGO nanosheets exhibited sensitive response to hydrogen sulfide (Rair/Rgas = 34 at 5 ppm) at 200 °C, whereas sensitive acetone detection (Rair/Rgas = 10 at 5 ppm) was achieved by increasing the RGO loading to 5 wt % and raising the operation temperature to 350 °C. The detection limit of these sensors is predicted to be as low as 1 ppm for hydrogen sulfide and 100 ppb for acetone, respectively. These concentrations are much lower than in the exhaled breath of healthy people. This demonstrates that optimization of the RGO loading and the operation temperature of RGO-SnO2 nanocomposite gas sensors enables highly sensitive and selective detection of breath markers for the diagnosis of diabetes and halitosis.
Diagnostic sensing device using exhaled breath of human have critical advantages due to the noninvasive diagnosis and high potential for portable device with simple analysis process. Here, we report ultrafast as well as highly sensitive bumpy WO3 hemitube nanostructure assisted by O2 plasma surface modification with functionalization of graphene-based material for the detection of acetone (CH3COCH3) and hydrogen sulfide (H2S) which are biomarkers for the diagnosis of diabetes and halitosis, respectively. 0.1 wt % graphene oxide (GO)- and 0.1 wt % thin layered graphite (GR)- WO3 hemitube composites showed response times of 11.5 ± 2.5 s and 13.5 ± 3.4 s to 1 ppm acetone as well as 12.5 ± 1.9 s and 10.0 ± 1.6 s to 1 ppm of H2S, respectively. In addition, low limits of detection (LOD) of 100 ppb (Rair/Rgas = 1.7 for acetone and Rair/Rgas = 3.3 for H2S at 300 °C) were achieved. The superior sensing properties were ascribed to the electronic sensitization of graphene based materials by modulating space charged layers at the interfaces between n-type WO3 hemitubes and p-type graphene based materials, as identified by Kelvin Probe Force Microscopy (KPFM). Rapid response and superior sensitivity of the proposed sensing materials following cyclic thermal aging demonstrates good potential for real-time exhaled breath diagnosis of diseases.
Field effect transistors (FETs), incorporating metal-oxide nanofibers as the active conductive channel, have the potential for driving the widespread application of nanowire or nanofiber FETs-based electronics. Here we report on low voltage FETs with integrated electrospun In2O3-ZnO-ZnGa2O4 composite fiber channel layers and high-K dielectric (MgO)0.3-(Bi1.5Zn1.0Nb1.5O7)0.7 gate insulator and compare their performance against FETs utilizing conductive single phase, polycrystalline ZnO or In2O3 channel layers. The polycrystalline In2O3-ZnO-ZnGa2O4 composite fibers provide superior performance with high field effect mobility (∼7.04 cm2 V(-1) s(-1)), low subthreshold swing (390 mV/dec), and low threshold voltage (1.0 V) combined with excellent saturation, likely resulting from the effective blocking of high current-flow through the In2O3 and ZnO nanocrystallites by the insulating spinel ZnGa2O4 phase. The microstructural evolution of the individual In2O3, ZnO, and ZnGa2O4 phases in composite fibers is clearly observed by high resolution TEM. A systematic examination of channel area coverage, ranging from single fiber to over 90% coverage, demonstrates that low coverage results in relatively low current outputs and reduced reproducibility which we attribute to the difficulty in positioning fibers and fiber length control. On the other hand, those with ∼80% coverage exhibited high field effect mobility, high on/off current ratios (>10(5)), and negligible hysteresis following 15 sweep voltage cycles. A special feature of this work is the application of the FETs to modulate the properties of complex polycrystalline nanocomposite channels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.