Raman spectroscopy (785 nm excitation) was used to determine the overall carotenoid (astaxanthin and cantaxanthin) and fat content in 49 samples of ground muscle tissue from farmed Atlantic salmon (Salmo salar L.). Chemically determined contents ranged from 1.0 to 6.8 mg/kg carotenoids and 36 to 205 g/kg fat. In addition to the raw Raman spectra, three types of spectral preprocessing were evaluated: the first derivative, subtraction of the fitted fourth-order polynomial (POLY), and the intensity normalized versions of POLY (POLY-SNV). Further, variable selection based on significance testing by use of jack-knifing was performed on each spectral data set. Partial least-squares regression resulted in a root mean square error of prediction of 0.33 mg/kg (R = 0.97) for carotenoids for the variable selected versions of all the preprocessed spectral data sets. The fat content was best estimated by the variable selected POLYSNV, resulting in a root mean square error of prediction of 15.5 g/kg (R = 0.95). Both preprocessing and variable selection improved the regression models significantly. The results demonstrate that Raman spectroscopy is a suitable method for simultaneous, rapid, and nondestructive quantification of both pigments and fat in ground salmon muscle tissue.
The development of a field portable fiber optic Raman system modified from commercially available components that can operate remotely on battery power and withstand the corrosive environment of the hydrothermal vents is discussed. The Raman system is designed for continuous monitoring in the deep-sea environment. A 785 nm diode laser was used in conjunction with a sapphire ball fiber optic Raman probe, single board computer, and a CCD detector. Using the system at ambient conditions the detection limits of SO(4)(2-), CO(3)(2-) and NO(3)(-) were determined to be approximately 0.11, 0.36 and 0.12 g l(-1) respectively. Mimicking the cold conditions of the sea floor by placing the equipment in a refrigerator yielded slightly worse detection limits of approximately 0.16 g l(-1) for SO(4)(-2) and 0.20 g l(-1) for NO(3)(-). Addition of minerals commonly found in vent fluid plumes also decreased the detection limits to approximately 0.33 and 0.34 g l(-1) respectively for SO(4)(-2) and NO(3)(-).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.