Parallel factor analysis (PARAFAC) is applied to three calibrations of a field-portable, cuvette-based, singlemeasurement, excitation-emission matrix fluorometer. In the first example the fluorometer is calibrated based on interactions between a non-fluorescent DDT-type pesticide and a fluorescent dye. PARAFAC is employed to deconvolve the fluorescence profiles of dissociated and complexed dye states. Calibration is performed based on the intensity of dye-pesticide fluorescence. In the second example, weighted PARAFAC (W-PARAFAC) is applied to determination of three polynuclear aromatic hydrocarbons (PAHs). The weighted algorithm is required to incorporate saturated channels of the CCD detector into the calibration model. In the third example, W-PARAFAC is applied to calibration of two carbamate pesticides. The weighted algorithm is required to account for Rayleigh and Raman scattering overlapping with the fluorescence spectra. For theses three applications, parts-per-trillion to parts-per-billion detection limits are observed in aqueous solutions. Copyright
SummaryCritical parameters for the separation of enkephalin related peptides by micellar electrokinetic chromatography were identified by using statistical experimental design. Nine experimental variables: micelle concentration, pH of the background electrolyte, addition of organic modifier to the background electrolyte, injection length, temperature of the capillary, applied voltage, ionic strength of the buffer, the composition of the injected solution and stacking were investigated in a twolevel fractional factorial design. The pH was found to be of fundamental importance but a great variation in separation performance was observed, subsequent modeling revealed two subgroups with respect to pH. For further screening of significant factors, the pH was kept constant and by using D-optimal design it was possible to study six interaction terms together with eight main effects in only 20 experiments. The effect of the interaction terms were often found to be as high as the main effects, thus exemplifying the complexity of the system. The effect of sodium dodecyl sulfate (SDS) concentration on efficiency and resolution was highly dependent on the amount of organic modifier, temperature and ionic strength. The migration factor calculated from obtained migration times was found to be a non-linear function of the factors involved. A complete separation within reasonable analysis time was obtained at the centre point.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.