BackgroundThe aim of this study was to investigate the efficacy of orthodontic treatment using the Invisalign® system. Particularly, we analyzed the influence of auxiliaries (Attachment/Power Ridge) as well as the staging (movement per aligner) on treatment efficacy.MethodsWe reviewed the tooth movements of 30 consecutive patients who required orthodontic treatment with Invisalign®. In all patients, one of the following tooth movements was performed: (1) Incisor Torque >10°, (2) Premolar derotation >10° (3) Molar distalization >1.5 mm. The groups (1)-(3) were subdivided: in the first subgroup (a) the movements were supported with the use of an attachment, while in the subgroup (b) no auxiliaries were used (except incisor torque, in which Power Ridges were used). All tooth movements were performed in a split-mouth design. To analyze the clinical efficacy, pre-treatment and final plaster cast models were laser-scanned and the achieved tooth movement was determined by way of a surface/surface matching algorithm. The results were compared with the amount of tooth movement predicted by ClinCheck®.ResultsThe overall mean efficacy was 59% (SD = 0.2). The mean accuracy for upper incisor torque was 42% (SD = 0.2). Premolar derotation showed the lowest accuracy with approximately 40% (SD = 0.3). Distalization of an upper molar was the most effective movement, with efficacy approximately 87% (SD = 0.2).ConclusionIncisor torque, premolar derotation and molar distalization can be performed using Invisalign® aligners. The staging (movement/aligner) and the total amount of planned movement have an significant impact on treatment efficacy.
Performed with aligners (Invisalign®), the resolvement of the partly severe anterior crowding was successfully accomplished. Resolving lower anterior crowding by protrusion of the anterior teeth (i.e., enlargement of the anterior arch length) seems well predictable. The initial ClinCheck® models provided high accuracy compared to the initial casts. The achieved tooth movement was in concordance with the predicted movement for all parameters, except for the overbite.
Lateral radiographs allow accurate and adequate assessment of vertical bone before paramedian insertion of palatal implants. The vertical bone dimension as displayed on lateral cephalometry reflects the minimum bone height rather than maximum bone in the median plane. Therefore, a preoperative CT or CBCT is only indicated when the lateral cephalometry reveals a marginal quantity of bone.
The IT-based transmission of mal-aligned teeth into the ClinCheck® presentation provides sufficiently good accuracy. Tooth corrections in the vertical plane were more difficult to realize. A vertical overcorrection in the final ClinCheck®, a case refinement at the end of the treatment or additional measures (e.g. horizontal beveled attachments or vertical elastics) seems useful to achieve the individually intended therapeutic goal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.