PurposeWe evaluate a matrix metalloproteinase-9 (MMP-9) point-of-care immunoassay (InflammaDry) as a prognostic tool for topical cyclosporine treatment.MethodsA total of 20 healthy subjects and 40 patients meeting >3 dry eye disease (DED) criteria (ocular surface disease index [OSDI] score ≥ 12, tear film breakup time [TBUT] ≤10 seconds, Schirmer I test result ≤10 mm/5 minutes, corneal staining ≥1) were included. DED patients were treated with topical cyclosporine ophthalmic emulsion 0.05% twice daily for 1 month. The InflammaDry test was used to grade MMP-9 levels in the tear film. Treatment response was monitored using the OSDI score, TBUT, and Schirmer, corneal staining, and InflammaDry tests.ResultsOf the eyes, 18 (22.5%) were negative, 29 (36.3%) trace-positive, 16 (20.0%) weak-positive, 11 (13.8%) positive, and six (7.5%) strong-positive for MMP-9 at baseline. MMP-9 levels correlated with OSDI (P = 0.049), TBUT (P = 0.001), corneal staining (P = 0.002), and Schirmer test (P = 0.027) results. MMP-9–positive patients displayed decreased post-treatment MMP-9 levels (P = 0.001) and corneal staining score (P < 0.001), improved OSDI score (P < 0.001), and increased TBUT (P < 0.001) and Schirmer (P = 0.009) test values.ConclusionsSemiquantitative MMP-9 grading correlated well with DED symptoms and signs, and could be used to predict patient status and monitor treatment response. MMP-9–positive patients responded more favorably to topical cyclosporine than did MMP-9–negative patients. Thus, the InflammaDry test may inform decisions regarding initiating topical cyclosporine treatment.Translational RelevanceSemiquantitative MMP-9 could be used to predict patient status and monitor treatment response.
The CT generally decreased with age, but it decreased much faster in old age than in relatively younger people. CT displayed large variations among different points in and outside of the vascular arcade. The thickest choroid was located at the point superior to the fovea, not the fovea itself. Such physiological variations should be considered when interpreting pathologic changes of the choroid.
Purpose: To evaluate topographic changes in choroidal thickness during development of choroidal neovascularization (CNV) in treatment-naive age-related macular degeneration (AMD) and to test the value of such changes as a predictive tool of CNV development. Methods: This retrospective cohort included 86 eyes that developed CNV from intermediate AMD, 43 eyes with intermediate AMD, and 36 eyes without AMD. Patients with intermediate AMD underwent spectral domain optical coherence tomography using enhanced depth imaging mode every 6 months until CNV was detected. Choroidal neovascularization was localized to one of the subfields of Early Treatment of Diabetic Retinopathy Study grid on fluorescein angiography. Average choroidal thickness of each subfield was calculated. Results: Choroidal thickness of the subfield where CNV developed at first clinical detection significantly increased compared with that 6 months before (P = 0.000 for central, P = 0.001 for superior parafoveal, P = 0.002 for temporal parafoveal, P = 0.002 for inferior parafoveal, and P = 0.001 for nasal parafoveal subfield). In eight patients who visited unexpectedly 3 months before CNV development in central subfield, choroidal thickness of central subfield increased significantly compared with that 6 months before CNV development (P = 0.001). Conclusion: Choroidal neovascularization development accompanied choroidal thickening of the corresponding subfield. Regular measurement of choroidal thickness may assist in prediction of CNV.
Purpose: To investigate the prevalence of normal intraocular pressure (IOP) at first visit among patients with primary angle-closure glaucoma (PACG) and their ocular characteristics. Patients and Methods: We retrospectively reviewed patients with PACG in a referral center. According to untreated IOP, we divided PACG eyes into 2 groups: those with normal IOP and those with high IOP (>21 mm Hg) at the first visit. Results: One hundred sixty eyes of 160 Korean PACG patients were included. Sixty percent (97/160) of the patients had normal IOP at their first visit. The PACG patients with initially normal IOP had significantly longer axial length (mean±SD, 22.99±0.76 vs. 22.74±0.61) and deeper “true” anterior chamber depth (ACD) (2.09±0.27 vs. 1.82±0.33) than those with initially high IOP (both P<0.05). Multiple logistic regression revealed that deeper “true” ACD (per 0.1 mm; odds ratio, 1.38) and more hyperopic refractive errors (odds ratio, 1.48) were independent predictors of initially normal IOP in PACG eyes (P<0.05). The prevalence of disc hemorrhage was higher in PACG patients with initially normal IOP than in those with initially high IOP (29.9% vs. 14.3%, P=0.029). Conclusions: Sixty percent of patients with PACG had normal IOP at their first visit. This suggests that without gonioscopy clinicians may misdiagnose PACG as normal tension glaucoma. ACD measurement can aid the diagnosis of PACG because even PACG eyes with initially normal IOP have shallow ACD.
Purpose To report a patient in whom a glaucomatous optic disc pit (ODP) disappeared spontaneously. Observations A 59-year-old Korean woman presented with primary open-angle glaucoma, an ODP, and deep superior cecocentral scotomas. She was treated with topical ocular hypotensive medications and followed. Twenty-eight months later, the superior cecocentral scotomas were not detectable with repeated visual field testing. With repeated optical coherence tomography (OCT), the ODP was narrower and shallower; partially filled with prelaminar tissue, there was an increase in the minimal rim width. At the final examination, the cecocentral scotomas reappeared, although prelaminar tissue continued to fill the ODP. Conclusions and importance ODP can disappear spontaneously in glaucomatous eyes under ocular hypotensive treatment. However, this is not always associated with sustained visual field improvement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.