The implantation of cardiac pacemakers has become a well-established therapy for conduction disorders and sinus node dysfunction. In many countries pacemaker registries have been initiated in order to collect information on patient characteristics, trends in numbers and the types of pacemakers used, to identify problematic devices, and for safety monitoring. For this utilisation study the Central Pacemaker Patients Registration (CPPR) from the Netherlands Pacemaker Registry Foundation (CPPR-SPRN) containing data collected for more than 20 years was used. During this period nearly 97,000 first pacemakers were implanted. Analyses show an increase in the rate of implanted devices. The change in pacemaker type from VVI to DDD, followed by biventricular stimulation, is reflected by the number of simultaneously implanted leads, which is partly a consequence of cardiac resynchronisation therapy. Our data demonstrate that indications for implantation and type of pacemaker are comparable with other European countries.
AimsAfter decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker.MethodsWe reviewed data collected between 1984 and 2006 in the first national Dutch pacemaker registry. This registry covered 96% of all generators implanted. We analysed the time of and reason for explantation of pacemaker generators. A 7-year follow-up interval after first implantation and following replacements was used to analyse changes over time.ResultsDuring 22 years of data collection, nearly 97,000 first pacemaker generators were implanted. A total of 27,937 (22.4%) generators were explanted within a mean of 6.3 (standard deviation 3.3) years. Reasons for approximately 60% of these explantations were ‘end of life’ of the pacemaker generator or elective system change. Complications or failures such as infections and recalls accounted for approximately 20% of the explantations. For the remaining 20%, the reasons for explantation had not been registered.ConclusionDespite progress in technology, a substantial proportion of pacemaker generators is explanted before its expected service time, with one in five generators being replaced due to technical failures, infections or other complications. Furthermore, the time interval between pacemaker implantation and explantation due to normal ‘end of life’ (battery EOL) decreased. Infections continue to rank highly as a cause for pacing system replacement, despite all current preventive measures.
This paper deals with the validation of the information stored in the Netherlands central pacemaker patient database. At this moment the registry database contains information on more than 70500 patients, 85000 pacemakers and 90000 leads. The validation procedures consisted of an internal consistency check and comparison with different hospital and pacemaker company databases. Although comparison of the exact information resulted in a meager agreement, the relevant information, based on the purpose of the database, proved to have the same accuracy as other registries. A number of suggestions to enhance the accuracy of this nationwide functioning database is mentioned.
Although the measurements during PM FU are according to guidelines, the frequency of FU is not. Moreover, in the vast majority of performed FU, PM programming is left unchanged. This suggests that a large portion of FU visits is redundant, such that their frequency after the first year can be diminished, or replaced by remote FU.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.