Purpose
To study the differentiation of malignant breast lesions from benign lesions and fibroglandular tissue (FGT) using apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM) parameters.
Materials and Methods
This retrospective study included 26 malignant and 14 benign breast lesions in 35 patients who underwent diffusion-weighted MRI at 3.0T and nine b-values (0–1000 s/mm2). ADC and IVIM parameters (perfusion fraction fp, pseudodiffusion coefficient Dp, and true diffusion coefficient Dd) were determined in lesions and FGT. For comparison, IVIM was also measured in 16 high-risk normal patients. A predictive model was constructed using linear discriminant analysis. Lesion discrimination based on ADC and IVIM parameters was assessed using receiver operating characteristic (ROC) and area under the ROC curve (AUC).
Results
In FGT of normal subjects, fp was 1.1 ± 1.1%. In malignant lesions, fp (6.4 ± 3.1%) was significantly higher than in benign lesions (3.1 ± 3.3%, P = 0.0025) or FGT (1.5 ± 1.2%, P < 0.001), and Dd ((1.29 ± 0.28) × 10−3 mm2/s) was lower than in benign lesions ((1.56 ± 0.28) × 10−3 mm2/s, P = 0.011) or FGT ((1.86 ± 0.34) × 10−3 mm2/s, P < 0.001). A combination of Dd and fp provided higher AUC for discrimination between malignant and benign lesions (0.84) or FGT (0.97) than ADC (0.72 and 0.86, respectively).
Conclusion
The IVIM parameters provide accurate identification of malignant lesions.
IMPORTANCE After neoadjuvant chemotherapy (NAC), pathologic complete response (pCR) is an optimal outcome and a surrogate end point for improved disease-free and overall survival. To date, surgical resection remains the only reliable method for diagnosing pCR. OBJECTIVE To evaluate the accuracy of magnetic resonance imaging (MRI)-guided biopsy for diagnosing a pCR after NAC compared with reference-standard surgical resection. DESIGN, SETTING, AND PARTICIPANTS Single-arm, phase 1, nonrandomized controlled trial in a single tertiary care cancer center from September 26, 2017, to July 29, 2019. The median follow-up was 1.26 years (interquartile range, 0.85-1.59 years). Data analysis was performed in November 2019. Eligible patients had (1) stage IA to IIIC biopsy-proven operable invasive breast cancer; (2) standardof-care NAC; (3) MRI before and after NAC, with imaging complete response defined as no residual enhancement on post-NAC MRI; and (4) definitive surgery. Patients were excluded if they were younger than 18 years, had a medical reason precluding study participation, or had a prior history of breast cancer. Open Access. This is an open access article distributed under the terms of the CC-BY License.
Our results demonstrate better image quality and reduced artifacts in rFOV images compared with large FOV DWI. Measurements from ADC maps derived from rFOV DWI show significantly lower ADC values when compared with ADC maps derived from large FOV DWI.
OBJECTIVE
We implemented an Image Quality Reporting and Tracking Solution (IQuaRTS), directly linked from the PACS, to improve communication between radiologists and technologists.
MATERIALS AND METHODS
IQuaRTS launched in May 2015. We compared MRI issues filed in the period before IQuaRTS implementation (May–September 2014) using a manual system with MRI issues filed in the IQuaRTS period (May–September 2015). The unpaired t test was used for analysis. For assessment of overall results in the IQuaRTS period alone, all issues filed across all modalities were included. Summary statistics and charts were generated using Excel and Tableau.
RESULTS
For MRI issues, the number of issues filed during the IQuaRTS period was 498 (2.5% of overall MRI examination volume) compared with 78 issues filed during the period before IQuaRTS implementation (0.4% of total examination volume) (p = 0.0001), representing a 625% relative increase. Tickets that documented excellent work were 8%. Other issues included images not pushed to PACS (20%), film library issues (19%), and documentation or labeling (8%). Of the issues filed, 55% were MRI-related and 25% were CT-related. The issues were stratified across six sites within our institution. Staff requiring additional training could be readily identified, and 80% of the issues were resolved within 72 hours.
CONCLUSION
IQuaRTS is a cost-effective online issue reporting tool that enables robust data collection and analytics to be incorporated into quality improvement programs. One limitation of the system is that it must be implemented in an environment where staff are receptive to quality improvement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.