PurposeThis study assessed the recurrence rate and other safety and efficacy parameters following ventral hernia repair with a polyester composite prosthesis (Parietex™ Composite Ventral Patch [PCO-VP]).Patients and methodsA single-arm, multicenter prospective study of 126 patients undergoing open ventral hernia repair with the PCO-VP was performed. Patient outcomes were assessed at discharge and at 10 days, 1, 6, 12, and 24 months postoperative.ResultsAll patients had hernioplasty for umbilical (n = 110, 87.3%) or epigastric hernia (n = 16, 12.7%). Mean hernia diameter was 1.8 ± 0.8 cm. Mean operative time was 36.2 ±15.6 minutes, with a mean mesh positioning time of 8.1 ± 3.4 minutes. Surgeons reported satisfaction with mesh ease of use in 95% of surgeries. The cumulative hernia recurrence rate at 1 year was 2.8% (3/106). Numeric Rating Scale (NRS) pain scores showed improvement from 2.1 ± 2.0 at preoperative baseline to 0.5 ± 0.7 at 1 month postoperative (P < 0.001), and this low pain level was maintained at 12 months postsurgery (P < 0.001). The mean global Carolina’s Comfort Scale® (CCS) score improved postoperatively from 3.8 ± 6.2 at 1 month to 1.6 ± 3.5 at 6 months (P < 0.001). One patient was unsatisfied with the procedure.ConclusionThis 1-year interim analysis using PCO-VP for primary umbilical and epigastric defects shows promising results in terms of mesh ease of use, postoperative pain, and patient satisfaction. Recurrence rate is low, but, as laparoscopic evaluation shows a need for patch repositioning in some cases, an accurate surgical technique remains of utmost importance.
Background This study assessed clinical outcomes, including safety and recurrence, from the two-year follow-up of patients who underwent open ventral primary hernia repair with the use of the Parietex™ Composite Ventral Patch (PCO-VP). Methods A prospective single-arm, multicenter study of 126 patients undergoing open ventral hernia repair for umbilical and epigastric hernias with the PCO-VP was performed. Results One hundred twenty-six subjects (110 with umbilical hernia and 16 with epigastric hernia) with a mean hernia diameter of 1.8 cm (0.4–4.0) were treated with PCO-VP. One hundred subjects completed the two-year study. Cumulative hernia recurrence was 3.0% (3/101; 95%CI: 0.0–6.3%) within 24 months. Median Numeric Rating Scale pain scores improved from 2 [0–10] at baseline to 0 [0–3] at 1 month ( P < 0.001) and remained low at 24 months 0 [0–6] ( P < 0.001). 99% (102/103) of the patients were satisfied with their repair at 24 months postoperative. Conclusions The use of PCO-VP to repair primary umbilical and epigastric defects yielded a low recurrence rate, low postoperative and chronic pain, and high satisfaction ratings, confirming that PCO-VP is effective for small ventral hernia repair in the two-year term after implantation. Trial registration The study was registered publically at clinicaltrials.gov ( NCT01848184 registered May 7, 2013).
Background One-year device safety and clinical outcomes of ventral hernia repair with the GORE® SYNECOR Intraperitoneal Biomaterial, a hybrid composite mesh was evaluated. Methods This retrospective, multicenter, case review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥ 1 year from study enrollment. Results Included were 459 patients (with 469 ventral hernias) with a mean age of 58 ± 15 years; 77.1% met Ventral Hernia Working Group 2 (VHWG2) classification. Mean hernia size was 18.9 cm2 and 57.3% of hernias were incisional. Laparoscopic or robotic approach was utilized in 95.4% of patients. Mesh location was intraperitoneal for 75.6% and bridging repair was performed in 57.3%. Procedure-related adverse events within 30-days occurred in 5.0% of patients and included surgical site infection (SSI), surgical site occurrence (SSO), ileus, readmission, and re-operation. Procedure-related SSI or SSO events were 3.8% through 12 months. SSO events requiring procedural intervention (SSOPI) were 2.6% through 24 months. Four patients (0.9%) had confirmed hernia recurrence through the study (the mean follow-up was 32-months, range 14–53 months). Subgroup comparisons were conducted for all type recurrence; only diabetes was found to be statistically significant (p = .0506). Conclusion In this analysis, ventral hernia repair with hybrid, composite mesh results in successful outcomes in most patients. This study represents a heterogeneous patient population undergoing repair using various approaches, mesh fixation, and mesh placement locations. These data appear to confirm long-term acceptable safety and device performance with a low rate of recurrence in a predominantly VHWG2 population.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.