ObjectivesThe objective of this study was to document the prevalence of feline blood types in the Iberian Peninsula and to determine the potential risk of incompatibility-related transfusion reactions in unmatched transfusions and the potential risk of neonatal isoerythrolysis (NI) in kittens born to parents of unknown blood type.MethodsBlood samples were obtained from blood donors of the Animal Blood Bank (BSA-Banco de Sangue Animal). Blood typing was performed using a card method (RapidVet-H Feline Blood Typing; MDS).ResultsThe studied population comprised 1070 purebred and non-purebred cats from Portugal and Spain aged between 1 and 8 years. Overall, frequencies of blood types A and B were 96.5% and 3.5%, respectively. No AB cats were found. Based on these data, the potential risks of NI and transfusion reactions in unmatched transfusions were calculated to be 6.8% and 2.8%, respectively.Conclusions and relevanceUnlike previous studies, no type AB cats were found in this study. Although the calculated potential risks of transfusion reaction in unmatched transfusions and neonatal isoerythrolysis were low, blood typing prior to blood transfusion and blood typing of cats for breeding purposes are highly recommended.
Background There is limited information about feline leishmaniosis (FeL) management in clinical practice. Leishmania infantum is the species of Leishmania most frequently reported in both dogs and cats in countries of the Mediterranean region (henceforth ‘Mediterranean countries’), Central and South America, and Iran. This study was conducted to provide veterinary clinicians with an updated overview of evidence-based information on leishmaniosis in cats. Methods A review was performed using PubMed, Science Direct, Google Scholar and Web of Science. Case reports of FeL caused by L. infantum were sought for the period 1912 to 1 June 2021. Results Sixty-three case reports are included in this review. Fifty-nine out of the 63 cats were from Europe, mostly from Mediterranean countries (88.9%). Most of them were domestic short-haired cats (90%) with a mean age of 7.9 years, and had access to the outdoors (77.3%). Sixty-six percent of the cats had comorbidities, of which feline immunodeficiency virus infection was the most frequent (37.7%). Dermatological lesions (69.8%) was the most frequent clinical sign, and hyperproteinemia (46.3%) the most frequent clinicopathological abnormality. Serology was the most performed diagnostic method (76.2%) and was positive for 93.7% of cats. Medical treatment was applied in 71.4% of cats, and allopurinol was the most used drug (74.4%). Survival time was greater for treated cats (520 days; 71.4% of cats) than non-treated cats (210 days; 25.4%). Conclusions The majority of the cats had comorbidities, of which feline immunodeficiency virus was the most frequent. Dermatological lesions were frequently reported, and systemic clinical signs and clinicopathological abnormalities were also common. Serology may be useful for the diagnosis of FeL in clinical practice, and a positive titer of ≥ 1/40 may be a useful cut-off for sick cats. The reported treatments and dosages varied, but there was a good clinical response and longer survival in most of the cats treated with allopurinol monotherapy. Graphical abstract
Objectives The most common use of plasma transfusion is for haemostatic purposes, but coagulation factor activities in stored feline plasma are unknown. The concentration and stability of coagulation factors I (fibrinogen), II, V, VII, VIII, IX, X, XI and XII in feline fresh frozen plasma (fFFP) stored for 1 year were studied. Methods Fifty-five units of fFFP were produced from 55 fresh whole-blood donations obtained from indoor healthy blood donor cats. Twenty-one units were stored for <2 weeks (T0) and 34 were stored for 1 year (T1). After the completion of storage, specific coagulation factor activities for factors II, V, VII, VIII, IX, X, XI and XII were tested using modified one-stage activated partial thromboplastin or prothrombin time assays. Fibrinogen was determined using the Clauss method. Results Significantly decreased activities were observed for factors II (T0: 101.94% ± 19.06%; T1: 73.23% ± 39.06% [ P = 0.001]), VII (T0: 102.78% ± 24.69%; T1: 60.08% ± 38.17% [ P <0.001]), VIII (T0: 77.52% ± 30.39%; T1: 50.32% ± 23.8% [ P = 0.001]), XI (T0: 88.76% ± 22.73%; T1: 66.28% ± 22.2% [ P = 0.001]) and XII (T0: 89.50% ± 21.85%; T1: 55.46% ± 23.18% [ P <0.001]) when comparing units at time 0 and after 1 year of storage. No significant difference was observed for factors IX (T0: 84.86% ± 29.35%; T1: 71.37% ± 22.23% [ P = 0.064]) and X (T0: 96.24% ± 25.1%; T1: 83.91% ± 49.54% [ P = 0.236]). Unexpectedly, a significant increase was observed for factor V (T0: 71.94% ± 24.14%; T1: 97.89% ± 62.33%; P = 0.046). Fibrinogen was 2.76 ± 1.09 g/l at T1. Factors VIII, XII and VII had the lowest mean activities after 1 year. Conclusions and relevance Although a decrease in most coagulation factors activities was noted with storage, 1-year-old fFFP was haemostatically active in vitro. The most suitable factors for quality control assessment of fFFP are factors VII and VIII. Approximately 13–20 ml/kg of fFFP is required to administer a minimum of 10 IU/kg coagulation factor activity.
Objectives Haemolysis caused by the use of peristaltic infusion pumps (PIPs) has been described in human and canine packed red blood cells (pRBCs). The aim of this study was to evaluate the effects of two different linear PIPs on the haemolysis of feline pRBC units stored for a long time. Methods Feline pRBC units stored with adenine, dextrose, mannitol and sodium chloride (SAGM) were manufactured. After 35–42 days of storage at 2–4°C, a line administration system with a 180 µm filter was attached to every pRBC bag, the system was drained by gravity alone (8 drops/min) and a 1.3 ml sample was collected (G). A NIKI V4 pump was then used at a flow rate of 25 ml/h, the flow was stopped when the infusion system was filled with blood coming from the infusion pump and another 1.3 ml sample was collected (NK). Finally, an Infusomat FmS pump was evaluated, collecting another 1.3 ml sample (IM). Packed cell volume (PCV) was measured in all samples by microhaematocrit centrifugation, total haemoglobin (HGB) was measured using a specific haemoglobin analyser and, after centrifugation, free HGB was determined by spectrophotometry. The percentage of haemolysis was calculated. Friedman’s test was used to compare the samples. Results Fifteen feline pRBC units were evaluated. The average degree of haemolysis for sample G (gravity-assisted) was 1.12%. Comparison of the degree of gravity-assisted haemolysis with haemolysis in PIP NK (1.13%) and IM (1.14%) samples revealed no significant differences, with differences of only 0.01% and 0.02%, respectively. Conclusions and relevance The results of this study demonstrate that the use of two common PIPs in veterinary hospitals does not produce levels of haemolysis that are significantly different than that caused by gravity alone during transfusion of feline pRBCs at a rate of 25 ml/h.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.