The objective of this paper is to present a new type of volumetric CT which uses the cone-beam technique instead of traditional fan-beam technique. The machine is dedicated to the dento-maxillo-facial imaging, particularly for planning in the field of implantology. The main characteristics of the unit are presented with reference to the technical parameters as well as the software performance. Images obtained are reported as various 2D sections of a volume reconstruction. Also, measurements of the geometric accuracy and the radiation dose absorbed by the patient are obtained using specific phantoms. Absorbed dose is compared with that given off by spiral CT. Geometric accuracy, evaluated with reference to various reconstruction modalities and different spatial orientations, is 0.8-1% for width measurements and 2.2% for height measurements. Radiation dose absorbed during the scan shows different profiles in central and peripheral axes. As regards the maximum value of the central profile, dose from the new unit is approximately one sixth that of traditional spiral CT. The new system appears to be very promising in dentomaxillo-facial imaging and, due to the good ratio between performance and low cost, together with low radiation dose, very interesting in view of large-scale use of the CT technique in such diagnostic applications.
A study was conducted on a group of 50 obese females with a mean body mass index of 39 +/- 16, aged 19 years, in order to determine if sonography could be adopted as a direct means for measuring intra-abdominal fat deposits. Adipose tissue evaluation was performed by computed tomography (CT) and ultrasonography (using 3.5-MHz and 5-MHz probes) at the L4 level. CT intra-abdominal fat area (VAT) and ultrasonography visceral thickness from abdominal muscle to aorta were the values mainly considered. Ultrasonographic intra-abdominal thickness correlated well with VAT (r = 0.669, p less than 0.001), supporting the hypothesis that ultrasonography could be useful in the direct evaluation of intra-abdominal fat deposits.
Due to the complexity of their developmental stages, the venae cavae may undergo a very large number of congenital anomalies. All the possible abnormalities which, to our knowledge, have been observed in the literature are reported, differentiating those of the superior vena cava and the azygos system, those of the inferior vena cava and the complex anomalies that concern the venous system as a whole. Moreover, we present three new variants: a right double inferior vena cava with azygos continuation of the posterior-medial vein; an agenesis of the superior vena cava with drainage through the azygos and hemiazygos veins to the inferior vena cava; and a double inferior vena cava with hemiazygos and azygos continuation of the left one.
As patients with previous history of pancreatitis were excluded from the study, CT findings allowed correct characterization of only 60% of cystic pancreatic masses. Among the remaining 40%, 15-20% of the wrong diagnoses could not be corrected by means of CT, given the patterns shown by the tumors. In 20-25% of the cases, a nonspecific diagnosis of cystic mass was made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.