Samples of commercial activated carbons (AC) obtained from different sources: Norit E Supra USP, Norit B Test EUR, and ML (Baracoa, Cuba) were investigated. The adsorption of acetaminophen, Co = 2500 mg/L, occured in simulated gastric fluid (SGF) at pH 1.2 in contact with activated carbon for 4 h at 310 K in water bath with stirring. Residual acetaminophen was monitored by UV visible. The results were converted to scale adsorption isotherms using alternative models: Langmuir TI and TII, Freundlich, Dubinin-Radushkevich (DR) and Temkin. Linearized forms of the characteristic parameters were obtained in each case. The models that best fit the experimental data were Langmuir TI and Temkin with R2 ≥0.98. The regression best fits followed the sequence: Langmuir TI = Temkin > DR > LangmuirTII > Freundlich. The microporosity determined by adsorption of CO2 at 273 K with a single term DR regression presented R2 > 0.98. The adsorption of acetaminophen may occur in specific sites and also in the basal region. It was determined that the adsorption process of acetaminophen on AC in SGF is spontaneous (ΔG <0) and exothermic (−ΔHads.). Moreover, the area occupied by the acetaminophen molecule was calculated with a relative error from 7.8 to 50%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.