The effect of lateral condensation using different tapered spreaders was evaluated. Curved mesiobuccal roots of maxillary molars were step-back prepared. Strain gauges applied to the root surfaces measured dentin deformation (distortion) during controlled lateral condensation with either fine finger or D11 spreaders. After obturation, roots were cross sectioned and analyzed under the stereomicroscope to detect the presence and pattern of fractures. The results showed no statistical difference between spreader designs as to mean distortion and the incidence of fractures; however several specimens in the D11 group showed high root distortion measurements. When fractures occurred, there were no consistent patterns of fracture in either spreader group. In conclusion, although there were no significant differences in mean deformation or fracture incidence in curved roots between the spreaders, the roots showing high deformation readings in the D11 group may be more susceptible to future vertical root fractures.
It has been recognised that ultrasonic files leave a diagonal pattern within the canal following endosonic instrumentation. There is confusion on the causative factor on the production of these marks. Furthermore there is little information about the marks produced by sonic files. An in vitro system consisting of highly polished dentin discs demonstrated that the ultrasonic K-file made a diagonal pattern that was an imprint of the cutting edges of the file. The sonic files produced different markings which were the result of their longitudinal and transverse motion. Root canals of extracted teeth were prepared with these instruments and similar grooves were observed. The ultrasonic K-file had diagonal grooves in the coronal and middle third of the root canal but longitudinal marks in the apical third. The rispisonic and shaper files produced debris even in the presence of NaOCl. This debris was formed into discrete parallel bands. Both longitudinal and transverse grooves were present and the canal had many other scratches similar to those seen with the dentin discs. There were differences between the marks produced by either ultrasonic or sonic endosonic instruments but it is unknown whether this influences the long term prognosis of the root canal therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.