The aims of this in vitro study were (1) to compare the reliability of a new fluorescence camera (FC; VistaProof) with that of two other laser fluorescence devices (DIAGNOdent and DIAGNOdent pen) in assessing smooth and occlusal caries lesions in primary teeth and (2) to determine the influence of the spacer, the protective cover and air drying on the FC readings. We selected 129 primary molars which were divided into two groups: smooth surfaces (n=68) and occlusal surfaces (n=61). Two trained examiners performed the evaluations using the FC and the other laser fluorescence devices separately. One examiner repeated all assessments after 1 week. Inter- and intraexaminer reproducibility was calculated from the absolute values derived from the devices using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Pearson correlation was performed among the values obtained with the different devices. For aim 2, only teeth from the occlusal surface group were used. Another examiner performed measurements with the FC, varying the size of the spacer, the use of the plastic protective cover and the drying time (0, 3 and 15 s). Wilcoxon's test was used to compare these measurements. High values of interexaminer ICC were observed with the FC in both experiments. However, the highest intraexaminer ICC for smooth surfaces was found for the DIAGNOdent (ICC 0.918). A positive correlation between all methods was observed in both studies. Only drying for 15 s significantly increased the FC readings. In conclusion, the FC showed high reliability for occlusal and smooth surfaces, similar to the other fluorescence methods tested. Additionally, prolonged air drying increased the FC measurements.
The aim of this study was to evaluate the influence of dental plaque and moisture on performance of a laser fluorescence device in detecting occlusal and proximal caries lesions in primary teeth. Fifty-five occlusal and 58 proximal sites on primary molars were evaluated using a DIAGNOdent pen (LFpen) device. For the drying time study, the evaluations were performed in: (I) moist teeth; (II) teeth dried for 3 s, or (III) dried for 15 s. For the plaque study, the evaluations were done in sites: (I) without plaque; (II) with plaque, and (III) after cleaning. Evaluation of the teeth sections in stereomicroscope was the reference standard method. LF pen values, sensitivity, specificity, and accuracy were compared. The values obtained after 15 s of drying were higher than those obtained with moist teeth or dried for 3 s at both occlusal and proximal surfaces. However, there was no change in the performance in detecting caries lesions. With regard to the presence of plaque, there was no significant change in the readings of the device, but specificity was decreased in occlusal surfaces with plaque. At proximal surfaces, however, no significant differences were observed. In conclusion, the moisture conditions do not influence significantly the performance of the LFpen, but the presence of plaque can affect its performance in detecting occlusal caries lesions in primary teeth.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.