There is a vital need for authentic COVID-19 animal models to enable the pre-clinical evaluation of candidate vaccines and therapeutics. Here we report a dose titration study of SARS-CoV-2 in the ferret model. After a high (5 × 106 pfu) and medium (5 × 104 pfu) dose of virus is delivered, intranasally, viral RNA shedding in the upper respiratory tract (URT) is observed in 6/6 animals, however, only 1/6 ferrets show similar signs after low dose (5 × 102 pfu) challenge. Following sequential culls pathological signs of mild multifocal bronchopneumonia in approximately 5–15% of the lung is seen on day 3, in high and medium dosed groups. Ferrets re-challenged, after virus shedding ceased, are fully protected from acute lung pathology. The endpoints of URT viral RNA replication & distinct lung pathology are observed most consistently in the high dose group. This ferret model of SARS-CoV-2 infection presents a mild clinical disease.
A novel coronavirus, SARS-CoV-2, has been identified as the causative agent of the current COVID-19 pandemic. Animal models, and in particular non-human primates, are essential to understand the pathogenesis of emerging diseases and to assess the safety and efficacy of novel vaccines and therapeutics. Here, we show that SARS-CoV-2 replicates in the upper and lower respiratory tract and causes pulmonary lesions in both rhesus and cynomolgus macaques. Immune responses against SARS-CoV-2 are also similar in both species and equivalent to those reported in milder infections and convalescent human patients. This finding is reiterated by our transcriptional analysis of respiratory samples revealing the global response to infection. We describe a new method for lung histopathology scoring that will provide a metric to enable clearer decision making for this key endpoint. In contrast to prior publications, in which rhesus are accepted to be the preferred study species, we provide convincing evidence that both macaque species authentically represent mild to moderate forms of COVID-19 observed in the majority of the human population and both species should be used to evaluate the safety and efficacy of interventions against SARS-CoV-2. Importantly, accessing cynomolgus macaques will greatly alleviate the pressures on current rhesus stocks.
The widespread dissemination of CTX-M extended spectrum β-lactamases among Escherichia coli bacteria, both in nosocomial and community environments, is a challenge for diagnostic bacteriology laboratories. We describe a rapid and sensitive detection system for analysis of DNA containing the blaCTX-M-15 gene using isothermal DNA amplification by recombinase polymerase amplification (RPA) on a digital microfluidic platform; active matrix electrowetting-on-dielectric (AM-EWOD). The devices have 16,800 electrodes that can be independently controlled to perform multiple and simultaneous droplet operations. The device includes an in-built impedance sensor for real time droplet position and size detection, an on-chip thermistor for temperature sensing and an integrated heater for regulating the droplet temperature. Automatic dispensing of droplets (45 nL) from reservoir electrodes is demonstrated with a coefficient of variation (CV) in volume of approximately 2%. The RPA reaction is monitored in real-time using exonuclease fluorescent probes. Continuous mixing of droplets during DNA amplification significantly improves target DNA detection by at least 100 times compared to a benchtop assay, enabling the detection of target DNA over four-order-of-magnitude with a limit of detection of a single copy within ~15 minutes.
A low cost thin-film transistor (TFT) nanoribbon (NR) sensor has been developed for rapid real-time detection of DNA amplification using an isothermal Recombinase Polymerase Amplification (RPA) method. The semiconductor chip measures DNA amplification through a pH change, rather than via fluorescence. The utility of the method was demonstrated by amplifying CTX-M and NDM, two genes that confer bacterial resistance to cephalosporins and carbapenems, respectively. It is shown that this approach provides extremely fast and sensitive detection. It can detect <10 copies of the gene in genomic DNA extracted from E. coli or K. pneumoniae clinical isolates within a few minutes. A differential readout system was developed to minimize the effect of primer-dimer amplification on the assay. The simple device has the potential for low cost, portable and real-time nucleic acid analysis as a Point of Care device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.