SUMMARY The accuracy of two-dimensional echocardiographic left ventricular volume measurement in an isolated heart preparation was tested using Simpson's reconstruction of progressively fewer short-axis cross sections of known location. Echocardiographic images from five ejecting hearts submerged in a special tank were obtained under conditions designed for maximal accuracy of echocardiographic volume assessment. Echocardiographic determinations of 52 volumes at various times throughout the cardiac cycle were compared, by least-squares linear regression, with simultaneous direct-volume measurements by volumetric chamber (range 9.4-44.8 ml). Echocardiographic and direct measurements correlated well for all numbers of cross sections from 1-19 (r = 0.84-0.97); however, variability of direct volume predicted from a given echocardiographic measurement increased nonlinearly as the number of cross sections per heart decreased, and was especially large when three or fewer cross sections were used (SEE = 4.6-7.1 ml). We previously used isolated, ejecting dog hearts to compare directly measured ventricular volume (without reliance on geometric assumptions) with echocardiographic volume obtained by reconstructing multiple cross-sectional images obtained at 3-mm intervals along the vertical axis of the heart.'0 Comparison of simultaneous data obtained throughout the cardiac cycle revealed not only a high correlation of echo to direct volume, but also a high predictive value of direct volume from any echocardiographic determination owing to low variability (r = 0.972, SEE = 2.93 ml, direct volume range 9.4-54.7 ml). These measurements were obtained under highly controlled conditions and it was not expected that the accuracy of echocardiographic volume determination could be matched in clinical use or in research applications in intact animals. At the very least, one could not obtain the large number of slices used in that study, and we did not assess the accuracy of volume changes with decreasing numbers of slices.Using the same preparation in the present study, but analyzing the data using progressively fewer slices, we found that at least four cross-sectional images of known location are required to predict ventricular volume without significant loss in accuracy.
Forty patients with aplastic anemia who were being considered for bone marrow transplantation were studied by in vivo and in vitro techniques to determine if the immune system in aplastic anemia is generally affected. It was found that patients with aplastic anemia had mild lymphopenia. with levels of circulating thymus-derived and bone-marrow-derived cells that were apparently secondarily depressed. Marked monocytopenia was observed. but this finding was mitigated by recovery of essentially normal numbers of mononuclear phagocytic cells (using a discontinuous Hypaque-Ficoll density gradient) and by the ability of patient mononuclear cells to participate at least as well as control cells geneic unrelated cells. Clinically the patients did not suffer from fungal or protozoal infections, which are common in immune deficiency syndromes. Thus these aplastic anemia patients were little different from normal subjects. The mild lymphopenia. impaired delayed hypersensitivity. and modestly depressed lgG and lgM levels were correlated with corticosteroid therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.