RF signals in VCOs, PLLs and synthesizers are characterized by signal power, harmonic content and phase noise. These parameters have to be accurately measured in order to guarantee the system performance. This paper focuses on the relationship between the signal's harmonic content and the precision of the phase noise measurement in test equipment. The phase noise measurement's accuracy is degraded when the measured signal has high harmonics. We demonstrate a case in which a 3 rd harmonic level of -7dBc results in a 12dB variation in the phase noise measurement's accuracy. Based on our studies, the phase noise test setup should include filters between the source and the test equipment to bring down the harmonic level to -20 dBc max.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.