Increased tidal volume and decreased chest wall compliance both increase the change in intrathoracic pressures and the value of the dynamic indices during mechanical ventilation. Additionally, the transmural pressure of the vena cava is decreased, whereas the transmural pressure of the right atrium is not changed.
Background
Hypotension is common during spinal anesthesia (SA) and is caused by a decrease in systemic vascular resistance (SVR) and/or cardiac output (CO). The effect of the dose of bupivacaine administered intrathecally on the changes in CO in elderly patients is largely unknown. This study investigated the hemodynamic effect of SA in elderly patients by studying the effect of two different dosages of intrathecal bupivacaine.
Methods
This prospective cohort study included 64 patients aged >65 years scheduled for procedures under SA; the patients received either 15 mg bupivacaine (the medium dose [MD] group) or 10 mg bupivacaine and 5 μg sufentanil (the low dose [LD] group). Blood pressure and CO were monitored throughout the procedure using Nexfin™, a noninvasive continuous monitoring device using a finger cuff.
Results
Thirty-three patients received MD and 31 received LD and there was no mean difference in baseline hemodynamics between the groups. On an average, the CO decreased 11.6% in the MD group and 10.0 % in the LD group. There was no significant change in SVR. Incidence of a clinically relevant decrease in stroke volume (SV) (>15% from baseline) was 67% in the MD and 45% in the LD groups (
P
<0.05).
Conclusion
CO and blood pressure decreased significantly after the onset of SA in elderly patients. This is mainly caused by a decrease in SV and not by a decrease in SVR. There was no difference in CO and blood pressure change between dosages of 10 or 15 mg bupivacaine.
The prototype device closely follows arterial pressure changes in children. However, in a considerable number of attempts, obtaining a signal was time-consuming or unsuccessful. This technique seems promising but requires further technical development.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.